Aims

Virtual reality (VR) offers an unrivalled immersive education opportunity to provide guaranteed pathology exposure, reproducible instruction and robust pathology recognition key performance indicators. We developed a novel VR platform to address the heterogenous and subjective nature of endoscopy education, which may contribute to the 11.3% published missed cancer rate of upper gastrointestinal endoscopy (EGD). Data demonstrates variability in the quality of endoscopic surveillance of Barrett’s esophagus (BE) but accurate assessment is vital to detect early neoplasia and alter the grave prognosis of esophageal adenocarcinoma. We conducted a pilot validation study for a novel prototype VR endoscopy training environment for Barrett’s esophagus.

Methods

32 endoscopists accredited to perform independent EGDs were recruited. Participants performed 3 virtual reality BE surveillance EGDs using Meta Quest 2 headset and were instructed to perform targeted biopsies on visible dysplasia. Feedback was collected using the validated Nasa Task Load Index (TLI), a 5-domain, 20-point Likert and the iGroup Presence Questionnaire (IPQ), a 3-domain, 7-point Likert. Intraclass co-efficients were used to assess inter-observer reliability for gastro-esophageal junction and Prague classification measurements. Visible dysplasia was present in 1/3 cases and was digitally rendered from a real case. Detection was recorded by successful biopsy of abnormal area.

Results

31/32 completed all 3 cases: 22 consultants, 6 trainee gastroenterologists, 4 nurse endoscopists. 95.7% identified the correct diagnosis of Barrett’s esophagus indicating good content validity. There was good interobserver reliability for gastro-esophageal junction and Prague measurements; intraclass co-efficient 0.84 (95% CI 0.72 – 0.92). 2/32 (6.3%) identified the dysplasia. There was no significant difference between consultant, trainee or nurse endoscopist (X2 p=0.572). The VR cases demonstrated construct validity: 4/32 (12.5%) were tertiary centre Barrett’s experts who were more likely to detect the lesion (likelihood ratio=9.4, X2 p

Zitieren

APA

Menabawey, T. E., Sinclair, A., Geffen, A., Webster, G., & Graham, D. (2024). Validation of a Virtual Reality Endoscopy Platform in Providing a Training Solution for Barrett’s Esophagus. Endoscopy, 56(S 02 S 02), S241-S242. https://doi.org/10.1055/s-0044-1783249

Vancouver

Menabawey TE, Sinclair A, Geffen A, Webster G, Graham D. Validation of a Virtual Reality Endoscopy Platform in Providing a Training Solution for Barrett’s Esophagus. Endoscopy. 2024;56(S 02 S 02):S241-S242. doi:10.1055/s-0044-1783249

BibTeX
@article{Menabawey2024,
  author = {Menabawey, T. El and Sinclair, A. and Geffen, A. and Webster, G. and Graham, D.},
  title = {Validation of a Virtual Reality Endoscopy Platform in Providing a Training Solution for Barrett’s Esophagus},
  journal = {Endoscopy},
  year = {2024},
  volume = {56},
  number = {S 02 S 02},
  pages = {S241--S242},
  doi = {10.1055/s-0044-1783249}
}
Kostenlos starten →