EUVIMEDEUVIMED entdecken
Systematische ÜbersichtMetaanalyse

Lack of Effectiveness of Computer Aided Detection for Colorectal Neoplasia: A Systematic Review and Meta-analysis of Non-Randomized Studies

H. Patel, M. Yuichi, C. Hassan, T. rizkala, D. Radadiya, P. Nathani, M. Misawa, M. Roberta, G. Antonelli, M. Spadaccini, K. Khalaf, A. Facciorusso und 3 weitere

Endoscopy · 01.04.2024 · 56 (S 02 S 02) · S208

DOI: 10.1055/s-0044-1783164 ↗

Kurz gefasst

Systematische Übersicht in der Zeitschrift Endoscopy, erschienen am 01.04.2024. Verfasst von H. Patel und 14 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aims

Benefits of computer-aided detection (CADe) in detecting colorectal neoplasia were shown in many randomized trials where endoscopists’ behavior was strictly controlled. However, the effect of CADe on endoscopists’ performance in less-controlled setting is unclear. This systematic review and meta-analyses were aimed at clarifying benefits and harms of using CADe in real-world colonoscopy.

Methods

We searched MEDLINE, EMBASE, Cochrane and Google Scholar from inception to August 20, 2023. We included non-randomized studies that compared the effectiveness between CADe-assisted and standard colonoscopy. Two investigators independently extracted study data and quality. Pairwise meta-analysis was performed utilizing Risk ratio (RR) for dichotomous variables and mean difference (MD) for continuous variables with a 95% confidence interval (95% CI).

Results

Eight studies were included, comprising 9,782 patients (4569 with CADe and 5213 without CADe). Regarding benefits, there was neither a difference in adenoma detection rate (44% vs 38%; RR 1.11 [95% CI 0.97 – 1.28]) nor mean adenoma per colonoscopy (0.93 vs 0.79; MD 0.14 [-0.04 – 0.32]) between the CADe-assisted and standard colonoscopy, respectively. Regarding harms, there was no difference in the mean non-neoplastic lesions per colonoscopy (8 studies included for analysis, 0.52 vs 0.47; MD 0.14 [95% CI -0.07 – 0.34]) and withdrawal time (6 studies included for analysis, 14.3 vs 13.4 minutes; MD 0.8 minutes [95% CI -0.18 – 1.90]). There was a substantial heterogeneity, and all outcomes were graded with a very low certainty of evidence.

Conclusions

CADe in colonoscopies neither improves the detection of colorectal neoplasia nor increases burden of colonoscopy in real-world, non-randomized studies, questioning the generalizability of the results of randomized trials. Publication History Article published online: 15 April 2024 © 2024. European Society of Gastrointestinal Endoscopy. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany

Zitieren

APA

Patel, H., Yuichi, M., Hassan, C., rizkala, T., Radadiya, D., Nathani, P., Misawa, M., Roberta, M., Antonelli, G., Spadaccini, M., Khalaf, K., Facciorusso, A., Douglas, K. R., Repici, A., & Sharma, P. (2024). Lack of Effectiveness of Computer Aided Detection for Colorectal Neoplasia: A Systematic Review and Meta-analysis of Non-Randomized Studies. Endoscopy, 56(S 02 S 02), S208. https://doi.org/10.1055/s-0044-1783164

Vancouver

Patel H, Yuichi M, Hassan C, rizkala T, Radadiya D, Nathani P, et al. Lack of Effectiveness of Computer Aided Detection for Colorectal Neoplasia: A Systematic Review and Meta-analysis of Non-Randomized Studies. Endoscopy. 2024;56(S 02 S 02):S208. doi:10.1055/s-0044-1783164

BibTeX
@article{Patel2024,
  author = {Patel, H. and Yuichi, M. and Hassan, C. and rizkala, T. and Radadiya, D. and Nathani, P. and Misawa, M. and Roberta, M. and Antonelli, G. and Spadaccini, M. and Khalaf, K. and Facciorusso, A. and Douglas, K. R. and Repici, A. and Sharma, P.},
  title = {Lack of Effectiveness of Computer Aided Detection for Colorectal Neoplasia: A Systematic Review and Meta-analysis of Non-Randomized Studies},
  journal = {Endoscopy},
  year = {2024},
  volume = {56},
  number = {S 02 S 02},
  pages = {S208},
  doi = {10.1055/s-0044-1783164}
}
Kostenlos starten →