EUVIMEDEUVIMED entdecken
Crossref

Different intragastric balloon’s fill volume: 500, 600, or 700 ml- any difference in outcome?

S. F. Vadalà Di Prampero, V. Cosseddu, S. Masia, P. Bazzu, C. Rocchi, M. Massidda, I. Bassu, A. Zuddas, K. Jankovic, N. Panic, P. Giustacchini, G. Costamagna und 1 weitere

Endoscopy · 01.04.2024 · 56 (S 02 S 02) · S194

DOI: 10.1055/s-0044-1783127 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Endoscopy, erschienen am 01.04.2024. Verfasst von S. F. Vadalà Di Prampero und 12 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aims

Obesity awareness has recently increased following its pandemic evolution. Besides nutritional and lifestyle modifications and pharmacological therapy, many other therapeutic strategies have been evaluated, with fluid-filled intragastric balloon (FF-IGB) being the most prevalent. There is still no consensus around which is the best fill volume for FF-IGB, that is usually filled according to the physician’s expertise, with the aim to tailor the filling on patient’s BMI and stomach dimension. This study aimed to focus on any differences concerning the fluid-filled intragastric balloon’s filling volume.

Methods

This was a single-center, observational prospective study of obese patients undergoing FF-IGB (Medsil, Orbera, or Spatz3) with a random fill volume of 500, 600, or 700 ml of saline and Methylene Blue. The outcomes were evaluation of post-procedural complications (pain, nausea, and vomiting), percentage of early removal for intolerance, percentage of Total Body Weight Loss (TBWL%), percentage of Excess Weight Loss (EWL%) and quality of Life (QoL) at 6 months follow-up according to different fill volume of 500, 600, or 700 ml.

Results

Between July 2020 and April 2023, 153 obese patients (41.7.5±9.02 kg/m2, 46.2±14 years) underwent FF-IGB. No differences were detected in post-procedural complications (pain p=0.180, nausea p=0.718, and vomiting p=0.480) or early removal (p=0.870). At 6 months follow-up the mean TBWL% was 14.6±7.14, EWL% was 30.8±23.30, with no differences among the three groups (p=0.882 and p=0.733, respectively). Also QoL improved at 1, 3, and 6 months follow-up and no differences among the three groups (p=0.819, p=0.822, p=0.849) were noticed.

Conclusions

An IGB’s fill volume of 500, 600, or 700 ml seems to be the same in terms of post-procedural complications, percentage of early removal for intolerance, TBWL%, EWL% and QoL at 6 months follow-up, independently of the initial patients' BMI. Publication History Article published online: 15 April 2024 © 2024. European Society of Gastrointestinal Endoscopy. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany

Zitieren

APA

Prampero, S. F. V. D., Cosseddu, V., Masia, S., Bazzu, P., Rocchi, C., Massidda, M., Bassu, I., Zuddas, A., Jankovic, K., Panic, N., Giustacchini, P., Costamagna, G., & Bulajic, M. (2024). Different intragastric balloon’s fill volume: 500, 600, or 700 ml- any difference in outcome?. Endoscopy, 56(S 02 S 02), S194. https://doi.org/10.1055/s-0044-1783127

Vancouver

Prampero SFVD, Cosseddu V, Masia S, Bazzu P, Rocchi C, Massidda M, et al. Different intragastric balloon’s fill volume: 500, 600, or 700 ml- any difference in outcome?. Endoscopy. 2024;56(S 02 S 02):S194. doi:10.1055/s-0044-1783127

BibTeX
@article{Prampero2024,
  author = {Prampero, S. F. Vadalà Di and Cosseddu, V. and Masia, S. and Bazzu, P. and Rocchi, C. and Massidda, M. and Bassu, I. and Zuddas, A. and Jankovic, K. and Panic, N. and Giustacchini, P. and Costamagna, G. and Bulajic, M.},
  title = {Different intragastric balloon’s fill volume: 500, 600, or 700 ml- any difference in outcome?},
  journal = {Endoscopy},
  year = {2024},
  volume = {56},
  number = {S 02 S 02},
  pages = {S194},
  doi = {10.1055/s-0044-1783127}
}
Kostenlos starten →