EUVIMEDEUVIMED entdecken
Crossref

Ergonomic analysis of functional colonoscopy simulations using inertial sensors

A. Rodriguez-D’jesús, M. Caeiro Rodriguez, F. A. Mikic-Fonte, A. Lugilde-López, M. Ayude Galego, M. M. Rodríguez González, A. Iglesias Doallo, D. Nogueira Senties, L. De Castro Parga, A. Martinez Turnes, J. I. Rodríguez Prada

Endoscopy · 01.04.2024 · 56 (S 02 S 02) · S186

DOI: 10.1055/s-0044-1783108 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Endoscopy, erschienen am 01.04.2024. Verfasst von A. Rodriguez-D’jesús und 10 weiteren Autor:innen. Die Arbeit nennt 6 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aims

Suboptimal ergonomics during colonoscopy procedures can lead to significant physical discomfort and fatigue for the endoscopist. The purpose of this study is to objectively analyze the ergonomic positions of endoscopists when performing colonoscopy procedures using a simulator and to assess the risk of potential injuries.

Methods

Eight endoscopists (4 experts and 4 novices) performed two colonoscopies on a model (Colonoscope Training Simulator M40 by Kyoto Kagaku INC), one being a simple procedure and the other complex, while wearing an inertial magnetic motion tracking suit (Xsens). Each participant used a total of 17 trackers. The simulations took place in a room with conditions similar to the real-world settings. The collected data were transmitted to a network application (Xsens MotionCloud) for automatic analysis of REBA and RULA. Finally, the professionals responded to a questionnaire to assess the extent to which operational postures subjectively affect their comfort (NASA Task Load Index).

Results

For the RULA, "low risk" is the more common result, with some "medium risk" periods representing in all cases less than 12% oh the whole duration. For the REBA the results are very similar, with "negligible" and "low risk" occurring more than 90% of the time, and "medium risk" periods representing in all cases less than 8%. High-risk values were very sporadic and occurred only in novice participants. Regardig the complexity of the intervention, results show a slightly higher risk in the complex procedure than in the simple procedure. Novice subjects and complex interventions took more time. The stage "from the beginning to the splenic flexure" involves a higher risk for novices than the other stages. [ 1 ] [ 2 ] [ 3 ] [ 4 ] [ 5 ] [ 6 ]

Conclusions

The results indicate a higher ergonomic risk for novices, aligning with findings from other studies and demonstrating the feasibility of data captured by sensors and automatic analysis software for generating evaluation reports compared to conventional human observers. Publication History Article published online: 15 April 2024 © 2024. European Society of Gastrointestinal Endoscopy. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany

Zitieren

APA

Rodriguez-D’jesús, A., Rodriguez, M. C., Mikic-Fonte, F. A., Lugilde-López, A., Galego, M. A., González, M. M. R., Doallo, A. I., Senties, D. N., Parga, L. D. C., Turnes, A. M., & Prada, J. I. R. (2024). Ergonomic analysis of functional colonoscopy simulations using inertial sensors. Endoscopy, 56(S 02 S 02), S186. https://doi.org/10.1055/s-0044-1783108

Vancouver

Rodriguez-D’jesús A, Rodriguez MC, Mikic-Fonte FA, Lugilde-López A, Galego MA, González MMR, et al. Ergonomic analysis of functional colonoscopy simulations using inertial sensors. Endoscopy. 2024;56(S 02 S 02):S186. doi:10.1055/s-0044-1783108

BibTeX
@article{RodriguezDjess2024,
  author = {Rodriguez-D’jesús, A. and Rodriguez, M. Caeiro and Mikic-Fonte, F. A. and Lugilde-López, A. and Galego, M. Ayude and González, M. M. Rodríguez and Doallo, A. Iglesias and Senties, D. Nogueira and Parga, L. De Castro and Turnes, A. Martinez and Prada, J. I. Rodríguez},
  title = {Ergonomic analysis of functional colonoscopy simulations using inertial sensors},
  journal = {Endoscopy},
  year = {2024},
  volume = {56},
  number = {S 02 S 02},
  pages = {S186},
  doi = {10.1055/s-0044-1783108}
}