Comparison of single use versus reusable gastroscope environmental impacts for an upper GI endoscopy procedure
Endoscopy · 01.04.2024 · 56 (S 02 S 02) · S183
DOI: 10.1055/s-0044-1783100 ↗Kurz gefasst
Fachartikel in der Zeitschrift Endoscopy, erschienen am 01.04.2024. Verfasst von M. Pioche und 5 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref).
Abstract (Originalsprache)
Aims
The environmental impact of endoscopy, including upper Gi endoscopy (UGE), has gained attention due to its contribution to the global carbon footprint. This study aimed to perform a life cycle assessment of the process of making an endoscope available for upper GI endoscopy, comparing disposable and reusable endoscopes.
Methods
Single use (Ambu Ascope Gastro) and reusable gastroscope (Olympus, H190) were evaluated using life cycle assessment methodology (ISO 14040), including analysis of scopes (components, assembly, distribution, use, end of life), disinfection and storage processes. An evaluation of the endoscopy column and washer impact based on monetary ratio was conducted to simulate scenarios of impacts in different settings.
Results
In single use and reusable strategies, climate change accounted respectively for 10.9 kgCO 2 eq and 4.7 kgCO 2 eq, fossil eq depletion for 130 MJ and 61MJ, water depletion for 6.4 and 9.5 m 3 per endoscope use. In the single use strategy. Based on monetary ratio, the endoscopy column accounted respectively for 4725 and 10080 kg CO 2 eq in the single use and reusable strategies, while the washer (reusable strategy) accounted for 7875 kg CO 2 eq. In a unit performing 1000 endoscopies/year, the column (and washer) account respectively for 0.47 kg CO 2 eq in single use strategy versus 1 (and 0.79) kg CO 2 eq reusable strategy.
Conclusions
For one upper GI endoscopy, single use endoscope is 2.5 more impacting than a reusable scope. Nevertheless, this difference is equivalent to a 17.5 km drive to reach the endoscopy unit compared to a local endoscopy with single use strategy. Publication History Article published online: 15 April 2024 © 2024. European Society of Gastrointestinal Endoscopy. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany
Zitieren
APA
Pioche, M., Rivory, J., Laporte, A., Jacques, J., Schaefer, M., & Berger, A. (2024). Comparison of single use versus reusable gastroscope environmental impacts for an upper GI endoscopy procedure. Endoscopy, 56(S 02 S 02), S183. https://doi.org/10.1055/s-0044-1783100
Vancouver
Pioche M, Rivory J, Laporte A, Jacques J, Schaefer M, Berger A. Comparison of single use versus reusable gastroscope environmental impacts for an upper GI endoscopy procedure. Endoscopy. 2024;56(S 02 S 02):S183. doi:10.1055/s-0044-1783100
BibTeX
@article{Pioche2024,
author = {Pioche, M. and Rivory, J. and Laporte, A. and Jacques, J. and Schaefer, M. and Berger, A.},
title = {Comparison of single use versus reusable gastroscope environmental impacts for an upper GI endoscopy procedure},
journal = {Endoscopy},
year = {2024},
volume = {56},
number = {S 02 S 02},
pages = {S183},
doi = {10.1055/s-0044-1783100}
}