Hot vs cold EMR: a well-known dualism in a north-eastern Italian experience
Endoscopy · 01.04.2024 · 56 (S 02 S 02) · S176
DOI: 10.1055/s-0044-1783085 ↗Kurz gefasst
Fachartikel in der Zeitschrift Endoscopy, erschienen am 01.04.2024. Verfasst von M. Bucci und 6 weiteren Autor:innen.
Abstract (Originalsprache)
Aims
Cold-EMR is nowadays thought to be associated with similar technical success rate and lower incidence of adverse events when compared with Hot-EMR. In our study, we aimed at comparing hot and cold-EMR, performed for colonic laterally spreading tumors (LST) and duodenal adenomas.
Methods
We conducted a monocentric retrospective study, enrolling all patients treated with hot-EMR or cold-EMR for LST or duodenal lesion larger than 10 mm in diameter, between January 2020 and November 2023 at Sant’Antonio Hospital in Padua. Chi-square test, Fisher Test and T-test were performed for categorical variables.
Results
During the study period, 268 EMR were performed (n=224 hot-EMR, n=44 cold-EMR). Two groups were homogenous according to mean lesion diameter (mm) (25.60±12.48 vs 24.36±15.19, p=0.2 ). The overall incidence of post procedural adverse events was significantly higher in hot-EMR group rather than cold-EMR group (26% vs. 7%; RR 3.76, p=0.018). Total bleeding events (early and delayed) were significantly more frequent after hot-EMR (21.9% vs. 6.8%; RR 3.22, p=0.04). Perforation occurred only in the group of patients in which was performed hot-EMR (n=8; 3.6%) with a significant statistical difference (p=0.001). Mean white blood cell count 24 hours after the procedure was significantly lower in cold-EMR group compared to hot-EMR (7.7±3.16 days vs 8.7±2.7 days; p=0.04). Our study also highlighted that cold-EMR significantly reduced procedure to discharge mean time compared to lesions removed with hot-EMR (2±1.12 days vs. 2.79±2.5 days; p=0.02). Besides, analysis of lesion recurrence rate did not show any significant statistical difference between the two techniques (4.5% in hot-EMR vs. 2.3% in cold-EMR; RR 1.95, p=0.50).
Conclusions
Our cohort analysis confirmed that cold-EMR is a safer resective technique, resulting in lower complication rate compared to hot-EMR, without a significant increase in recurrence rate. Publication History Article published online: 15 April 2024 © 2024. European Society of Gastrointestinal Endoscopy. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany
Zitieren
APA
Bucci, M., Corrà, G., Gubbiotti, A., Peraro, L., Caroli, D., Guido, E., & Rizzotto, E. R. (2024). Hot vs cold EMR: a well-known dualism in a north-eastern Italian experience. Endoscopy, 56(S 02 S 02), S176. https://doi.org/10.1055/s-0044-1783085
Vancouver
Bucci M, Corrà G, Gubbiotti A, Peraro L, Caroli D, Guido E, et al. Hot vs cold EMR: a well-known dualism in a north-eastern Italian experience. Endoscopy. 2024;56(S 02 S 02):S176. doi:10.1055/s-0044-1783085
BibTeX
@article{Bucci2024,
author = {Bucci, M. and Corrà, G. and Gubbiotti, A. and Peraro, L. and Caroli, D. and Guido, E. and Rizzotto, E. Rosa},
title = {Hot vs cold EMR: a well-known dualism in a north-eastern Italian experience},
journal = {Endoscopy},
year = {2024},
volume = {56},
number = {S 02 S 02},
pages = {S176},
doi = {10.1055/s-0044-1783085}
}
EUVIMED