EUVIMEDEUVIMED entdecken
Crossref

Comparison of diagnostic accuracy of endocytoscopy and probe-based confocal laser endomicroscopy

A. Y. Lee, J. Y. Seo, S. H. Kim, J. Y. Cho

Endoscopy · 01.04.2024 · 56 (S 02 S 02) · S159

DOI: 10.1055/s-0044-1783039 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Endoscopy, erschienen am 01.04.2024. Verfasst von A. Y. Lee und 3 weiteren Autor:innen. Die Arbeit nennt 6 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aims

Traditionally, biopsies have been regarded as the most accurate method for diagnosing gastrointestinal systems. However, the risks of sampling errors and post-biopsy inflammatory changes can make endoscopic procedures challenging. Therefore, in vivo methods have gained importance, with endocytoscopy and probe-based confocal laser endomicroscopy (pCLE) emerging as prominent techniques. Despite their significance, there has been no study comparing these two methods to date. This retrospective study aims to compare the accuracy and clinical utility of these two diagnostic approaches.

Methods

In this study, a total of 110 patients with various gastrointestinal lesions were examined using pCLE and dye-based endocytoscopy. The primary objective was to compare the sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and overall accuracy of these diagnostic methods. The secondary outcomes included comparing the rate of obtaining diagnostically viable images with each method and evaluating the organ-specific diagnostic rates when both methods were used in conjunction.

Results

The study found that pCLE had a sensitivity of 100% (95% CI: 94.42% to 100%), specificity of 78.57% (95% CI: 52.41% to 92.43%), positive predictive value (PPV) of 95.59% (95% CI: 87.81% to 98.49%), negative predictive value (NPV) of 100% (95% CI: 74.12% to 100%), and an overall accuracy of 96.20% (95% CI: 89.42% to 98.70%). In comparison, endocytoscopy showed a sensitivity of 47.69% (95% CI: 36.02% to 59.62%), specificity of 85.71% (95% CI: 60.06% to 95.99%), PPV of 93.94% (95% CI: 80.39% to 98.32%), NPV of 26.09% (95% CI: 15.60% to 40.26%), and accuracy of 54.43% (95% CI: 43.50% to 64.95%). The differences in sensitivity, NPV, and accuracy between the two groups were statistically significant ( P value

Zitieren

APA

Lee, A. Y., Seo, J. Y., Kim, S. H., & Cho, J. Y. (2024). Comparison of diagnostic accuracy of endocytoscopy and probe-based confocal laser endomicroscopy. Endoscopy, 56(S 02 S 02), S159. https://doi.org/10.1055/s-0044-1783039

Vancouver

Lee AY, Seo JY, Kim SH, Cho JY. Comparison of diagnostic accuracy of endocytoscopy and probe-based confocal laser endomicroscopy. Endoscopy. 2024;56(S 02 S 02):S159. doi:10.1055/s-0044-1783039

BibTeX
@article{Lee2024,
  author = {Lee, A. Y. and Seo, J. Y. and Kim, S. H. and Cho, J. Y.},
  title = {Comparison of diagnostic accuracy of endocytoscopy and probe-based confocal laser endomicroscopy},
  journal = {Endoscopy},
  year = {2024},
  volume = {56},
  number = {S 02 S 02},
  pages = {S159},
  doi = {10.1055/s-0044-1783039}
}
Kostenlos starten →