A comparative study benchmarking colon polyp detection with CADe software

N. Papachrysos, P. H. Smedsrud, K. Anonsen, T. J. Berstad, H. Espeland, A. Petlund, P. Hedenström, P. Halvorsen, J. Varkey, H. Hammer, M. Riegler, T. de Lange

Endoscopy · 01.04.2024 · 56 (S 02 S 02) · S92-S93

DOI: 10.1055/s-0044-1782889 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Endoscopy, erschienen am 01.04.2024. Verfasst von N. Papachrysos und 11 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aims

Some studies have shown that Computer-Aided Detection software (CADe) for real-time colonic polyp detection improves polyp detection and adenoma detection rate (ADR), but no head-to-head comparison of different commercially available CADe systems has been performed. This study aims to compare the performance of three different polyp detection systems using a novel standardized methodology.

Methods

Three hundred colonoscopies were video recorded and short video clips (25–40 seconds) representing normal segments or segments containing a polyp were randomly selected. These videos were then streamed through each CADe system from the manufacturers Medtronic, Olympus, and Augere Medical. Each system had various configurations or versions, resulting in a total of six distinct CADe software settings that were compared to each other with respect to sensitivity, specificity and the false positive rate (FPR). We also assess five endoscopists performance regarding both polyp detection and reaction time and compared it to the CADe systems.

Results

All the CADe system had a high sensitivity for polyp detection ranging from 90%–100%, but a more than four-fold difference in the false positive rates (FPR) per frame ranging from 1.2% to 5.6%. Overall, the CADe systems achieving the highest sensitivity also had the highest FPR, or most false alerts potentially distracting the endoscopists. The differences between the systems were statistically significant (p-value

Zitieren

APA

Papachrysos, N., Smedsrud, P. H., Anonsen, K., Berstad, T. J., Espeland, H., Petlund, A., Hedenström, P., Halvorsen, P., Varkey, J., Hammer, H., Riegler, M., & Lange, T. D. (2024). A comparative study benchmarking colon polyp detection with CADe software. Endoscopy, 56(S 02 S 02), S92-S93. https://doi.org/10.1055/s-0044-1782889

Vancouver

Papachrysos N, Smedsrud PH, Anonsen K, Berstad TJ, Espeland H, Petlund A, et al. A comparative study benchmarking colon polyp detection with CADe software. Endoscopy. 2024;56(S 02 S 02):S92-S93. doi:10.1055/s-0044-1782889

BibTeX
@article{Papachrysos2024,
  author = {Papachrysos, N. and Smedsrud, P. H. and Anonsen, K. and Berstad, T. J. and Espeland, H. and Petlund, A. and Hedenström, P. and Halvorsen, P. and Varkey, J. and Hammer, H. and Riegler, M. and Lange, T. de},
  title = {A comparative study benchmarking colon polyp detection with CADe software},
  journal = {Endoscopy},
  year = {2024},
  volume = {56},
  number = {S 02 S 02},
  pages = {S92--S93},
  doi = {10.1055/s-0044-1782889}
}
Kostenlos starten →