EUVIMEDEUVIMED entdecken
Crossref

Effect of cecal intubation rate on adenoma and serrated polyp detection and the impact on post colonoscopy colorectal cancer deaths

J. Zessner-Spitzenberg, E. Waldmann, B. Majcher, P. Daniela, A. Demschik, L. M. Rockenbauer, M. Trauner, M. Ferlitsch

Endoscopy · 01.04.2024 · 56 (S 02 S 02) · S69

DOI: 10.1055/s-0044-1782836 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Endoscopy, erschienen am 01.04.2024. Verfasst von J. Zessner-Spitzenberg und 7 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aims

The visualization of the whole colonic mucosa due to complete colonoscopy with caecal intubation has been accepted as a quality parameter for screening colonoscopy. However, there is little evidence of the caecal intubation rate and its association with long-term patient outcome.

Methods

We did a linkage of individuals that participated in the Austrian Quality Assurance Program to the Austrian death registry to obtain information on deaths of post-colonoscopy colorectal cancer. We performed logistic regression to estimate the association of baseline characteristics with caecal intubation as well as the caecal intubation rate with the probability to detect adenomas or proximal serrated polyps.

Results

381460 screening participants between 01/2010 and 12/2022 were included in this analysis. We found that for with every one percentage point increase in the CIR, the probability to detect an adenoma increased by five percentage points (OR 1.05, 95% CI 1.052 – 1.0576, p

Zitieren

APA

Zessner-Spitzenberg, J., Waldmann, E., Majcher, B., Daniela, P., Demschik, A., Rockenbauer, L. M., Trauner, M., & Ferlitsch, M. (2024). Effect of cecal intubation rate on adenoma and serrated polyp detection and the impact on post colonoscopy colorectal cancer deaths. Endoscopy, 56(S 02 S 02), S69. https://doi.org/10.1055/s-0044-1782836

Vancouver

Zessner-Spitzenberg J, Waldmann E, Majcher B, Daniela P, Demschik A, Rockenbauer LM, et al. Effect of cecal intubation rate on adenoma and serrated polyp detection and the impact on post colonoscopy colorectal cancer deaths. Endoscopy. 2024;56(S 02 S 02):S69. doi:10.1055/s-0044-1782836

BibTeX
@article{ZessnerSpitzenberg2024,
  author = {Zessner-Spitzenberg, J. and Waldmann, E. and Majcher, B. and Daniela, P. and Demschik, A. and Rockenbauer, L. M. and Trauner, M. and Ferlitsch, M.},
  title = {Effect of cecal intubation rate on adenoma and serrated polyp detection and the impact on post colonoscopy colorectal cancer deaths},
  journal = {Endoscopy},
  year = {2024},
  volume = {56},
  number = {S 02 S 02},
  pages = {S69},
  doi = {10.1055/s-0044-1782836}
}
Kostenlos starten →