Adenomas per colonoscopy is superior to adenoma detection rate as a quality indicator of colonoscopy
Endoscopy · 01.04.2024 · 56 (S 02 S 02) · S68
DOI: 10.1055/s-0044-1782833 ↗Kurz gefasst
Fachartikel in der Zeitschrift Endoscopy, erschienen am 01.04.2024. Verfasst von Y. S. Suh und 6 weiteren Autor:innen.
Abstract (Originalsprache)
Aims
Adenoma detection rate (ADR) is most widely used as a quality indicator of colonoscopy because of facileness of calculation. Another indicator, adenoma miss rate (AMR) is most critical tool of the quality of colonoscopy, but not easy to calculate routinely. In our study, we assessed to figure out association of AMR with several easy-calculatable quality indicators of not only ADR but also adenomas per colonoscopy (APC), adenomas per positive participant (APP) and ADR-plus.
Methods
Four indicators (ADR, ADR-plus, APC, and APP) and two gold standard indicators (AMR and AMR_5mm) were analyzed from colonoscopies performed between 2011 and 2019 in Korea University Ansan Hospital. To derive AMR, we compared two different colonoscopies from same patient, of which interval was 36 months or less. AMR in this study was defined as “the number of adenomas detected in the second colonoscopy per the number of all adenomas detected in the first and second colonoscopy” and AMR_5mm was derived with adenomas only with size of 5mm or larger. If there were more than 10 adenomas detected in the first examination, those cases were excluded. Cases of patient with age under 40 were also excluded. And colonoscopies from endoscopies who performed less than total 50 examinations were not included.
Results
Total 682 colonoscopy cases were analyzed retrospectively. Mean age was 58.9 and male was 440(65%). Mean time interval between exams was 22.0 months. AMR for each endoscopist was ranged from 0.24 to 0.52 (mean 0.37) and AMR_5mm was from 0.23 to 0.57 (mean 0.35). ADR and APP were not significantly correlated with AMR (ADR, r=-0.493, p=0.177; APP, r=0.167, p=0.688) or AMR_5mm (ADR, r=-0.493, p=0.177; APP=-0.478, p=0.193). However, APC and ADR-plus exhibited a strong negative correlation with AMR_5mm (APC, r=-0.770, p=0.015; ADR-plus, r=-0.713, p=0.031).
Conclusions
APC had a significant negative association with AMR_5mm, in contrast to ADR that showed no correlation with AMR or AMR_5mm. The result means APC might be a better quality indicator than ADR for a meticulous endoscopist. Publication History Article published online: 15 April 2024 © 2024. European Society of Gastrointestinal Endoscopy. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany
Zitieren
APA
Suh, Y. S., Koo, J. S., Kim, D. W., Shin, H. K., Kim, J. W., Choi, D. K., & Park, K. H. (2024). Adenomas per colonoscopy is superior to adenoma detection rate as a quality indicator of colonoscopy. Endoscopy, 56(S 02 S 02), S68. https://doi.org/10.1055/s-0044-1782833
Vancouver
Suh YS, Koo JS, Kim DW, Shin HK, Kim JW, Choi DK, et al. Adenomas per colonoscopy is superior to adenoma detection rate as a quality indicator of colonoscopy. Endoscopy. 2024;56(S 02 S 02):S68. doi:10.1055/s-0044-1782833
BibTeX
@article{Suh2024,
author = {Suh, Y. S. and Koo, J. S. and Kim, D. W. and Shin, H. K. and Kim, J. W. and Choi, D. K. and Park, K. H.},
title = {Adenomas per colonoscopy is superior to adenoma detection rate as a quality indicator of colonoscopy},
journal = {Endoscopy},
year = {2024},
volume = {56},
number = {S 02 S 02},
pages = {S68},
doi = {10.1055/s-0044-1782833}
}
EUVIMED