EUVIMEDEUVIMED entdecken
Crossref

Adequacy, safety and technical determinants of modified endoscopic ultrasound guided liver biopsy technique: A pilot study

B. R. Patra, S. Pujalwar, S. Gupta, S. Harindranath, A. Vaidya, T. Laxane, J. Yadav, P. Mane, A. Shukla

Endoscopy · 01.04.2024 · 56 (S 02 S 02) · S49

DOI: 10.1055/s-0044-1782790 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Endoscopy, erschienen am 01.04.2024. Verfasst von B. R. Patra und 8 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aims

Endoscopic ultrasound-guided liver biopsy (EUS-LB) has emerged as a safe alternative to percutaneous route. Tissue acquisition technique related factors as a determinant of specimen yield has not been studied. We adapted a modified technique of EUS-LB to study the adequacy, safety and technical determinants of higher yield.

Methods

A prospective observational study was conducted from July to November 2023. All consecutive patients requiring liver biopsy were included. EUS-LB was performed with 19G Franseen core needle by wet heparinised suction technique. One to two passes were taken either through the transgastric or transduodenal (if former not feasible) route with multiple actuations till blood was aspirated into the suction syringe. Aspiration of blood into the suction syringe was used as a dynamic end point for biopsy actuations. Post procedure the syringe was detached with the stopcock closed and thereafter plunger of syringe was gently unlocked to release the residual negative pressure prior to opening of stopcock. Then the content in syringe and needle was transferred into a petri dish containing formalin and specimen cores were identified and separated. Outcome measured were total and longest specimen length (TSL and LSL), number of complete portal tracts (CPT) and definitive histological diagnosis. TSL, LSL and number of specimen cores were correlated with number and depth of actuations. An adequate specimen was defined as TSL≥20 mm and CPT≥11. Only TSL was considered when CPT could not be counted due to cirrhosis.

Results

Fifty patients (non cirrhotics or chronic hepatitis-27, compensated cirrhosis-14, decompensated cirrhosis-9) were included in the study. The percentage of adequate tissue samples were seen in 48 patients (96%). A final histologic diagnosis could be made in 49 patients (98%). Mean TSL was 7.98 cm (±3.74) and mean LSL was 1.89 cm (±0.80). Mean CPT was 24.32 (±9.60) excluding 8 patients (16%) in whom portal tracts could not be counted due to stage 5/6 fibrosis. The mean number of specimen cores obtained per patient were 8.74 (±3.65). Mean depth of actuation was 4.29cm (±0.98) and mean number of actuation was 6.95 (±2.04). The correlation between TSL in non cirrhotics vs cirrhotics with number and depth of actuation were r=0.71 vs 0.53 & r=0.55 vs 0.51. Similarly correlation between LSL in non cirrhotics vs cirrhotics with depth and number of actuation were r=0.74 vs 0.55 & r=0.28 vs 0.11. There was no significant correlation between number of specimen cores with either number or depth of actuation. Persistent needle track bleeding was observed in one patient which subsided after blood plugging. Post procedural mild pain and sedation related vomiting was seen in two patient each. No major adverse events were seen.

Conclusions

This study validates use of our modified EUS-LB technique in achieving superior tissue acquisition, lesser pain scores while being safe both for non cirrhotic and cirrhotic subjects. It also proves that technical parameters like number and depth of actuation determines specimen yield. Publication History Article published online: 15 April 2024 © 2024. European Society of Gastrointestinal Endoscopy. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany

Zitieren

APA

Patra, B. R., Pujalwar, S., Gupta, S., Harindranath, S., Vaidya, A., Laxane, T., Yadav, J., Mane, P., & Shukla, A. (2024). Adequacy, safety and technical determinants of modified endoscopic ultrasound guided liver biopsy technique: A pilot study. Endoscopy, 56(S 02 S 02), S49. https://doi.org/10.1055/s-0044-1782790

Vancouver

Patra BR, Pujalwar S, Gupta S, Harindranath S, Vaidya A, Laxane T, et al. Adequacy, safety and technical determinants of modified endoscopic ultrasound guided liver biopsy technique: A pilot study. Endoscopy. 2024;56(S 02 S 02):S49. doi:10.1055/s-0044-1782790

BibTeX
@article{Patra2024,
  author = {Patra, B. R. and Pujalwar, S. and Gupta, S. and Harindranath, S. and Vaidya, A. and Laxane, T. and Yadav, J. and Mane, P. and Shukla, A.},
  title = {Adequacy, safety and technical determinants of modified endoscopic ultrasound guided liver biopsy technique: A pilot study},
  journal = {Endoscopy},
  year = {2024},
  volume = {56},
  number = {S 02 S 02},
  pages = {S49},
  doi = {10.1055/s-0044-1782790}
}
Kostenlos starten →