EUVIMEDEUVIMED entdecken
Crossref

Periprosthetic Hip Heterotopic Ossification after Electrocution

Gloria Coden, Kurt V. Johnson, Olivia Bono, James V. Bono

The Journal of Hip Surgery · 01.12.2024 · 08 (04) · 239-241

DOI: 10.1055/s-0044-1782513 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Journal of Hip Surgery, erschienen am 01.12.2024. Verfasst von Gloria Coden und 3 weiteren Autor:innen. Die Arbeit nennt 12 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Heterotopic ossification is not only a common occurrence following total hip arthroplasty, but also may follow burn injuries. Uncommonly, this entity may become symptomatic when associated with a hip replacement and even less commonly presents in a delayed fashion years after the procedure. Case Presentation We describe a case in which symptomatic periprosthetic heterotopic ossification was identified years after total hip replacement, but only months following an electrical injury.

Conclusion

Patients with prosthetic joint replacements may be at risk for symptomatic periprosthetic heterotopic ossification following an electrocution event due to electrical conduction through the prosthesis and surrounding tissues.

Zitieren

APA

Coden, G., Johnson, K. V., Bono, O., & Bono, J. V. (2024). Periprosthetic Hip Heterotopic Ossification after Electrocution. The Journal of Hip Surgery, 08(04), 239-241. https://doi.org/10.1055/s-0044-1782513

Vancouver

Coden G, Johnson KV, Bono O, Bono JV. Periprosthetic Hip Heterotopic Ossification after Electrocution. The Journal of Hip Surgery. 2024;08(04):239-241. doi:10.1055/s-0044-1782513

BibTeX
@article{Coden2024,
  author = {Coden, Gloria and Johnson, Kurt V. and Bono, Olivia and Bono, James V.},
  title = {Periprosthetic Hip Heterotopic Ossification after Electrocution},
  journal = {The Journal of Hip Surgery},
  year = {2024},
  volume = {08},
  number = {04},
  pages = {239--241},
  doi = {10.1055/s-0044-1782513}
}