EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Influence of Different Apical Foramen Morphologies on the Accuracy of Four Electronic Foramen Locators

Renan D Furlan, Murilo P Alcalde, Rodrigo R Vivan, Michel E Klymus, Ana G S Limoeiro, Marco A H Duarte, Bruno C de Vasconcelos iD

European Journal of Dentistry · 01.10.2024 · 18 (04) · 1101-1106

DOI: 10.1055/s-0044-1782214 ↗

Kurz gefasst

Fachartikel in der Zeitschrift European Journal of Dentistry, erschienen am 01.10.2024. Verfasst von Renan D Furlan und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Dentistry, Endodontics and Dental Materials, Bauru Dental School, University of São Paulo, Bauru, SP, Brazil. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

The aim of this study was to evaluate the accuracy of the Root ZX II (RZX), Raypex 6 (RAY), EPex Pro (EPEX), and CanalPro (CNP) electronic foramen locators (EFLs) in different foraminal morphologies (fully formed foramen, immature foramen with parallel walls, and immature foramen with divergent walls); this article also evaluated the influence of different penetration levels (0.0 mm and −1.0 mm). Materials and Methods Thirty single-rooted human premolars were accessed and had their cervical/middle thirds prepared with SX ProTaper files. The apical foramens (AF) were standardized to 250 µm and the initial root canal length (RCL1) was measured under 16x magnification with aid of a digital caliper. Using the alginate model, electronic measurements (EM) were taken 1.0 mm up to AF (EM1/-1) and at AF (EM1/0), always using adjusted hand K-files. The root apexes were then cross-sectioned 3.0 mm from the foramen; then, new RCL (RCL2) and electronic measurements were performed (EM2/-1 and EM2/0.0). Finally, retropreparations were performed with instruments SX ProTaper files introduced 4.0 mm in the apicocervical direction. Then new RCL (RCL3) and electronic measurements (EM3/-1 and EM3/0) were performed. Statistical Analysis Values were tabulated and tested for normality using the Shapiro–Wilk test, which yielded nonparametric distributions of the data. Data were subjected to the Kruskal–Wallis and Dunn tests to estimate possible differences between devices as a function of foramen morphology and/or apical limit. The significance level was set at 5.0%.

Results

In general, the EFLs were accurate in determining the RCL. Statistically significant differences were observed between EPEX and RAY at 0.0, when measuring the divergent AF canals (p < 0.05). Regarding the different foramen morphologies in each EFL, RZX and EPEX showed no interference (p > 0.05), whereas RAY and CNP had lower accuracy levels at 0.0 with divergent AF (p < 0.05).

Conclusion

The four devices evaluated are accurate to determine the RCL in the conditions tested. The apical limit of penetration did not have significant influence on their accuracy. Conversely, the presence of divergence in the AF walls negatively influenced de RAY and CNP precisions at the foraminal level.

Autor:innen und Institutionen

  • Department of Dentistry, Endodontics and Dental Materials, Bauru Dental School, University of São Paulo, Bauru, SP, Brazil.
  • Post-Graduate Program in Dentistry, School of Pharmacy, Dentistry and Nursing, Federal University of Ceará, Fortaleza, Ceará, Brazil.
  • School of Dentistry of Sobral, Federal University of Ceará, Campus Sobral, Sobral, CE, Brazil.

ORCID-Profile: Bruno C de Vasconcelos

Zitieren

APA

Furlan, R. D., Alcalde, M. P., Vivan, R. R., Klymus, M. E., Limoeiro, A. G. S., Duarte, M. A. H., & de Vasconcelos, B. C. (2024). Influence of Different Apical Foramen Morphologies on the Accuracy of Four Electronic Foramen Locators. European Journal of Dentistry, 18(04), 1101-1106. https://doi.org/10.1055/s-0044-1782214

Vancouver

Furlan RD, Alcalde MP, Vivan RR, Klymus ME, Limoeiro AGS, Duarte MAH, et al. Influence of Different Apical Foramen Morphologies on the Accuracy of Four Electronic Foramen Locators. European Journal of Dentistry. 2024;18(04):1101-1106. doi:10.1055/s-0044-1782214

BibTeX
@article{Furlan2024,
  author = {Furlan, Renan D and Alcalde, Murilo P and Vivan, Rodrigo R and Klymus, Michel E and Limoeiro, Ana G S and Duarte, Marco A H and de Vasconcelos, Bruno C},
  title = {Influence of Different Apical Foramen Morphologies on the Accuracy of Four Electronic Foramen Locators},
  journal = {European Journal of Dentistry},
  year = {2024},
  volume = {18},
  number = {04},
  pages = {1101--1106},
  doi = {10.1055/s-0044-1782214}
}
Kostenlos starten →