Comparison of Two-Dimensional IOTA Simple Rules and Three-Dimensional Ultrasonography in Preoperative Assessment of Adnexal Masses
Indian Journal of Radiology and Imaging · 01.10.2024 · 34 (04) · 588-595
DOI: 10.1055/s-0044-1779734 ↗Kurz gefasst
Fachartikel in der Zeitschrift Indian Journal of Radiology and Imaging, erschienen am 01.10.2024. Verfasst von Rishu Goel und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Obstetrics & Gynaecology, All India Institute of Medical Sciences, New Delhi, India. Die Arbeit nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Objective
Accurate preoperative characterization of adnexal masses is essential for optimal patient management. Two-dimensional ultrasonography (USG) based “International Ovarian Tumuor Analysis Simple Rules (IOTA-SR)” are used primarily in clinical practice. Three-dimensional (3D) USG is an emerging modality. The authors conducted this study to compare the performance of 3D USG with IOTA-SR for preoperative differentiation of benign and malignant adnexal masses.
Methods
This prospective observational study recruited 84 patients with adnexal masses undergoing surgical management. IOTA-SR and 3D USG with power Doppler examination were applied to characterize the masses and correlated with histopathology. Logistic regression analysis defined individual 2D and 3D USG parameters' significance in predicting malignancy. The receiver operating characteristic (ROC) curve was plotted for significant variables, and area under the curves (AUCs) with cut-off values were calculated using the Youden index.
Results
Out of the 84 adnexal masses, 41 were benign and 43 were malignant. IOTA-SR were conclusive in 88.1% (74/84) cases, with a sensitivity of 83.78% (95% confidence interval [CI]: 67.99–93.81%) and specificity of 89.19% (95% CI: 74.58–96.97%). The sensitivity and specificity of 3D USG with power Doppler were 84% and 88%, respectively, with an AUC of 0.96 (95% CI: 0.92–0.99). Ten cases were inconclusive by the IOTA-SR, and 3D USG could further correctly differentiate four of these cases.
Conclusion
The diagnostic performance of both techniques is comparable. With good diagnostic performance and easy applicability, IOTA-SR remain the standard of care. 3D USG, although a more objective assessment, requires further validation and standardization.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Obstetrics & Gynaecology, All India Institute of Medical Sciences, New Delhi, India.
- Department of Radiodiagnosis, All India Institute of Medical Sciences, New Delhi, India.
ORCID-Profile: Smita Manchanda
Zitieren
APA
Goel, R., Singhal, S., Manchanda, S., Rajan, S., Meena, J., & Bharti, J. (2024). Comparison of Two-Dimensional IOTA Simple Rules and Three-Dimensional Ultrasonography in Preoperative Assessment of Adnexal Masses. Indian Journal of Radiology and Imaging, 34(04), 588-595. https://doi.org/10.1055/s-0044-1779734
Vancouver
Goel R, Singhal S, Manchanda S, Rajan S, Meena J, Bharti J. Comparison of Two-Dimensional IOTA Simple Rules and Three-Dimensional Ultrasonography in Preoperative Assessment of Adnexal Masses. Indian Journal of Radiology and Imaging. 2024;34(04):588-595. doi:10.1055/s-0044-1779734
BibTeX
@article{Goel2024,
author = {Goel, Rishu and Singhal, Seema and Manchanda, Smita and Rajan, Saroj and Meena, Jyoti and Bharti, Juhi},
title = {Comparison of Two-Dimensional IOTA Simple Rules and Three-Dimensional Ultrasonography in Preoperative Assessment of Adnexal Masses},
journal = {Indian Journal of Radiology and Imaging},
year = {2024},
volume = {34},
number = {04},
pages = {588--595},
doi = {10.1055/s-0044-1779734}
}
EUVIMED