EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Correlative Factors of Severity of Air Bubbles in the Large Intestine during Colonoscopy

Takaaki Yoshikawa, Atsushi Yamauchi, Kumi Itami, Shinichiro Odo, Yoshihiro Soma, Kosuke Tanaka, Kazuki Negoro, Yuki Mori, Kazuki Osawa, Ryou Itou, Yuya Kawai, Sota Nakagami und 8 weitere

Journal of Digestive Endoscopy · 01.03.2024 · 15 (01) · 18-26

DOI: 10.1055/s-0044-1779617 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Digestive Endoscopy, erschienen am 01.03.2024. Verfasst von Takaaki Yoshikawa und 19 weiteren Autor:innen. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

The condition of air bubbles in the large intestine is an influential factor for good quality of colonoscopy. However, the correlative factors of severity of air bubbles during colonoscopy in the large intestine are not established. Therefore, this study aimed to elucidate the correlative factors influencing the severity of air bubbles in the large intestine. Materials and Methods A total of 314 examinees who underwent colonoscopy between August and September 2022 were enrolled (median age [range], 65 [18–88] years). Air bubbles were scored using the Colon Endoscopic Bubble Scale (CEBuS) and the clinical factors associated with the CEBuS scores, especially in the ileocecum, were analyzed.

Results

In this study, 39.8% (125/314) of examinees harbored severe air bubbles in the ileocecum. Multiple linear regression analysis revealed that the CEBuS scores in the ileocecum were positively associated with the interval time from completion of bowel preparation to intubation of the cecum (p = 0.0016) and a history of cholecystectomy (p = 0.0198). Logistic regression analysis between no, mild, and moderate air bubbles group (n = 189) and severe air bubbles group (n = 125) also showed that severity was positively associated with the interval time from completion of bowel preparation to intubation of the cecum (p = 0.0332) and a history of cholecystectomy (p = 0.0095).

Conclusion

Interval time and history of cholecystectomy were associated with severity of air bubbles in the large intestine after bowel preparation.

Zitieren

APA

Yoshikawa, T., Yamauchi, A., Itami, K., Odo, S., Soma, Y., Tanaka, K., Negoro, K., Mori, Y., Osawa, K., Itou, R., Kawai, Y., Nakagami, S., Azuma, S., Morita, T., Hirohashi, K., Kuriyama, K., Takahashi, K., Kou, T., Katayama, T., & Yazumi, S. (2024). Correlative Factors of Severity of Air Bubbles in the Large Intestine during Colonoscopy. Journal of Digestive Endoscopy, 15(01), 18-26. https://doi.org/10.1055/s-0044-1779617

Vancouver

Yoshikawa T, Yamauchi A, Itami K, Odo S, Soma Y, Tanaka K, et al. Correlative Factors of Severity of Air Bubbles in the Large Intestine during Colonoscopy. Journal of Digestive Endoscopy. 2024;15(01):18-26. doi:10.1055/s-0044-1779617

BibTeX
@article{Yoshikawa2024,
  author = {Yoshikawa, Takaaki and Yamauchi, Atsushi and Itami, Kumi and Odo, Shinichiro and Soma, Yoshihiro and Tanaka, Kosuke and Negoro, Kazuki and Mori, Yuki and Osawa, Kazuki and Itou, Ryou and Kawai, Yuya and Nakagami, Sota and Azuma, Shunjiro and Morita, Toshihiro and Hirohashi, Kenshiro and Kuriyama, Katsutoshi and Takahashi, Ken and Kou, Tadayuki and Katayama, Toshiro and Yazumi, Shujiro},
  title = {Correlative Factors of Severity of Air Bubbles in the Large Intestine during Colonoscopy},
  journal = {Journal of Digestive Endoscopy},
  year = {2024},
  volume = {15},
  number = {01},
  pages = {18--26},
  doi = {10.1055/s-0044-1779617}
}
Kostenlos starten →