EUVIMEDEUVIMED entdecken
Crossref

Results of a Highly Porous Metal-Backed Cementless Patella Implant: A Minimum 5-Year Follow-Up

James F Baker, Nolan S Smith, Elive F Likine, Langan S Smith, Madhusudhan R Yakkanti, Arthur L Malkani

The Journal of Knee Surgery · 01.03.2024 · 37 (04) · 267-274

DOI: 10.1055/s-0043-56997 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Journal of Knee Surgery, erschienen am 01.03.2024. Verfasst von James F Baker und 5 weiteren Autor:innen. Beteiligte Einrichtung: ULP Orthopedics, UofL Health, Louisville, Kentucky. Hauptthemen laut MEDLINE: Knee Prosthesis, Arthroplasty, Replacement, Knee. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 43 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Initial design cementless metal-backed patellar implants failed due to multiple reasons including implant design, use of first-generation polyethylene, and surgical technique. This study evaluates clinical outcomes and survivorship of total knee arthroplasty (TKA) using a current generation highly porous metal-backed patellar component. One-hundred twenty-five consecutive primary cementless TKAs with a compression molded highly porous metal-backed patella were reviewed. One-hundred three TKAs (82.4%) with 5-year clinical and radiographic follow-up were available for review. These were matched with 103 consecutive TKAs using a cemented patella of the same implant design. The cementless cohort had a mean age of 65.5 years, body mass index (BMI) of 33.0, and follow-up of 64.4 months. Indications for cementless TKA were based on multiple factors including age, BMI, and bone quality. There were no revisions for loosening or mechanical failure of the cementless patella compared with two cemented patellae revised for aseptic loosening. Eight patients required revisions in the cementless cohort: three for prosthetic joint infection (PJI), two for instability, one periprosthetic femur fracture, one for patella instability, and one for extensor mechanism rupture. Five patients required revisions in the cemented cohort: two for aseptic patellar loosening, one for aseptic femoral loosening, one for PJI, and one for instability. All-cause survivorship at 5 years was 92.2 and 95.1% for the cementless metal-backed implant and cemented implant cohorts, respectively. Use of a compression molded highly porous metal-backed patella component demonstrated excellent clinical and radiographic results at 5-year follow-up. Longer follow-up is required to evaluate the ability of highly porous cementless patella implants to provide durable long-term fixation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Knee ProsthesisArthroplasty, Replacement, KneeHumansAgedPatellaFollow-Up StudiesPorosityMetalsReoperationProsthesis DesignTreatment OutcomeProsthesis Failure

Substanzen

Metals

Autor:innen und Institutionen

  • ULP Orthopedics, UofL Health, Louisville, Kentucky.
  • University of Louisville School of Medicine, Louisville, Kentucky.
  • Department of Orthopedic Surgery, University of Louisville, Louisville, Kentucky.
  • Louisville Orthopaedic Clinic, Louisville, Kentucky.
  • Adult Reconstruction Program, Department of Orthopedic Surgery, University of Louisville, Louisville, Kentucky.

Zitieren

APA

Baker, J. F., Smith, N. S., Likine, E. F., Smith, L. S., Yakkanti, M. R., & Malkani, A. L. (2024). Results of a Highly Porous Metal-Backed Cementless Patella Implant: A Minimum 5-Year Follow-Up. The Journal of Knee Surgery, 37(04), 267-274. https://doi.org/10.1055/s-0043-56997

Vancouver

Baker JF, Smith NS, Likine EF, Smith LS, Yakkanti MR, Malkani AL. Results of a Highly Porous Metal-Backed Cementless Patella Implant: A Minimum 5-Year Follow-Up. The Journal of Knee Surgery. 2024;37(04):267-274. doi:10.1055/s-0043-56997

BibTeX
@article{Baker2024,
  author = {Baker, James F and Smith, Nolan S and Likine, Elive F and Smith, Langan S and Yakkanti, Madhusudhan R and Malkani, Arthur L},
  title = {Results of a Highly Porous Metal-Backed Cementless Patella Implant: A Minimum 5-Year Follow-Up},
  journal = {The Journal of Knee Surgery},
  year = {2024},
  volume = {37},
  number = {04},
  pages = {267--274},
  doi = {10.1055/s-0043-56997}
}
Kostenlos starten →