EUVIMEDEUVIMED entdecken
Crossref

Finnegan score revisited by analysis of clinical routine electronic data

T. Rech, K. Rubarth, C. Bührer, F. Balzer, C. Dame

Zeitschrift für Geburtshilfe und Neonatologie · 01.11.2023 · 227 (S 01 S 01) · e234

DOI: 10.1055/s-0043-1776630 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Zeitschrift für Geburtshilfe und Neonatologie, erschienen am 01.11.2023. Verfasst von T. Rech und 4 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

After exposure to opioids, neonatal abstinence syndrome (NAS) is routinely measured by the Finnegan score (FS), which is comprised of various clinical symptoms and their rated severity. The FS is laborious and subjective, so alternative ways of assessing neonatal opioid withdrawal may reduce workload and improve quality of care . In this pilot study, we examined associations between the FS and routine monitoring data obtained from the electronic health record system, such as vital parameter readings and medication, demonstrating feasibility of data acquisition and analysis.

Methods

We included n=205 patients, among them n=23 with primary ( in-utero exposure) and n=182 with iatrogenic NAS (postnatal opioid exposure), who received withdrawal assessment by FS. Patients without documented medication and without clearly differentiated exposure type (pre/postnatal) were excluded from the analysis. To analyze routine monitoring data, two time periods were set: t-1 at 60±10 min and t-2 at 120±10 min before each FS assessment. Within each time period, we calculated the mean for each vital parameter and – to reduce individual variability – normalized readings to an individual baseline calculated per patient and parameter. We calculated mixed effects models to assess the effect of the different variables.

Results

Plots of vital parameters against the FS show heavily scattered data. When controlling for several variables, the best-performing mixed effects models displayed significant effects of individual baseline-controlled mean heart rate (Estimate: 0.04; 95%-CI 0.02-0.07) and arterial blood pressure (Estimate: 0.06; 95%-CI 0.02-0.09) at t-1 with R 2 m =0.11.

Conclusion

Routine electronic data can be extracted and analyzed for correlation with Finnegan score data. After normalizing vital parameters to an individual baseline, mixed effects models show small but significant effects for heart rate and mean arterial blood pressure – yet the data remains scattered. The scatter might be reduced by higher data frequency and correction for more variables. However, the limited relationship between routine monitoring data and FS rather supports moving from the FS to the "Eat, Sleep, Console" approach to assess neonatal opioid withdrawal. Funding-Source: Berlin University Alliance Award-ID: 822_Dame_CHA Funding-Statement: Funding of research exchange costs to Oxford, UK. Publication History Article published online: 15 November 2023 © 2023. Thieme. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany

Zitieren

APA

Rech, T., Rubarth, K., Bührer, C., Balzer, F., & Dame, C. (2023). Finnegan score revisited by analysis of clinical routine electronic data. Zeitschrift für Geburtshilfe und Neonatologie, 227(S 01 S 01), e234. https://doi.org/10.1055/s-0043-1776630

Vancouver

Rech T, Rubarth K, Bührer C, Balzer F, Dame C. Finnegan score revisited by analysis of clinical routine electronic data. Zeitschrift für Geburtshilfe und Neonatologie. 2023;227(S 01 S 01):e234. doi:10.1055/s-0043-1776630

BibTeX
@article{Rech2023,
  author = {Rech, T. and Rubarth, K. and Bührer, C. and Balzer, F. and Dame, C.},
  title = {Finnegan score revisited by analysis of clinical routine electronic data},
  journal = {Zeitschrift für Geburtshilfe und Neonatologie},
  year = {2023},
  volume = {227},
  number = {S 01 S 01},
  pages = {e234},
  doi = {10.1055/s-0043-1776630}
}
Kostenlos starten →