EUVIMEDEUVIMED entdecken
Crossref

D-dimer levels during pregnancy and postpartum: non-applicability of regularly used cut-offs for diagnosis of suspected pulmonary embolism

E. Ranieri, R. Brun, N. Ochsenbein-Köble, W. Korte, C. Haslinger

Zeitschrift für Geburtshilfe und Neonatologie · 01.11.2023 · 227 (S 01 S 01) · e217

DOI: 10.1055/s-0043-1776587 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Zeitschrift für Geburtshilfe und Neonatologie, erschienen am 01.11.2023. Verfasst von E. Ranieri und 4 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Pregnancy represents a prothrombotic state with consequently increased risk of thromboembolic complications. In clinical practice outside pregnancy, D-dimer measurement plays an important role in the diagnostic workup of thromboembolic complications; however, due to the physiological increase of D-dimers in pregnancy, there are no established cut-off values for parturient women. Nonetheless, the Artemis1 study recently included D-dimer levels in the evaluation of a pregnancy-adapted YEARS algorithm for the diagnosis of suspected pulmonary embolism. Objective of this study was to analyze pre- and postpartum D-dimer values of 1309 parturient women, stratified per gestational age at delivery, with a particular interest on the amount of women with apparently no thromboembolic complication but D-dimer values above cut-offs currently in use in diagnostic algorithms (0.5 or 1.0 mg/L).

Methods

This secondary analysis of a prospective cohort study ("PPH 1300 study") was conducted at a tertiary hospital between October 2015 and November 2016 including 1309 pregnant women from 25 to 42 weeks of gestation. Women were stratified for gestational age at delivery: group A (25+0 – 29+6 weeks of pregnancy, n=10), group B (30+0 – 34+6, n=17), group C (35+0 – 36+6, n=49) and group D (37+0 – 42+3, n=1233). Blood samples for D-dimer measurement were drawn in the 36 hours before onset of delivery and 24 to 48 hours after delivery.

Results

Overall, measured D-dimer values were 1.56 (1.20-2.12) mg/L prepartum and 1.78 (1.25-2.84) mg/L postpartum, data depicted as median (interquartile range). Referring to the above mentioned cut-offs, 1300 women (99.3%) had prepartum D-dimers≥0.5mg/L and 1163 women (88.8%)≥1.0mg/L; in the postpartum period 1293 women (98.8%) and 1153 women (88.1%) were above the cut-off of 0.5mg/L and 1.0mg/L, respectively. When stratifying for gestational age, prepartum D-dimers values showed a rising trend with increasing gestational age, while postpartum values did not differ significantly between groups. The percentage of prepartum women with D-dimers>0.5mg/L />1.0mg/L in groups A, B, C, and D was 80% / 60%, 100% / 76.5%, 100% / 95.9%, and 99.4% / 89%, respectively, and 100% / 90%, 100% / 88.2%, 98% / 87.8%, and 98.8% / 88.1% in the postpartum setting, stratified per group.

Conclusion

Our results suggest that the integration of D-dimer cut-off values in the diagnostic workup of suspected pulmonary embolism, as proposed in the Artemis1 study using a pregnancy-adapted YEARS algorithm, is not applicable. In our population, 99% of women had D-dimer values above 0.5mg/L and 88% of women values above 1.0 mg/L, both in the pre- and postpartum setting. Hence, it is questionable to base the decision whether to perform a computed tomography or not on certain cut-offs for D-dimer values [ 1 ]. Publication History Article published online: 15 November 2023 © 2023. Thieme. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany

Zitieren

APA

Ranieri, E., Brun, R., Ochsenbein-Köble, N., Korte, W., & Haslinger, C. (2023). D-dimer levels during pregnancy and postpartum: non-applicability of regularly used cut-offs for diagnosis of suspected pulmonary embolism. Zeitschrift für Geburtshilfe und Neonatologie, 227(S 01 S 01), e217. https://doi.org/10.1055/s-0043-1776587

Vancouver

Ranieri E, Brun R, Ochsenbein-Köble N, Korte W, Haslinger C. D-dimer levels during pregnancy and postpartum: non-applicability of regularly used cut-offs for diagnosis of suspected pulmonary embolism. Zeitschrift für Geburtshilfe und Neonatologie. 2023;227(S 01 S 01):e217. doi:10.1055/s-0043-1776587

BibTeX
@article{Ranieri2023,
  author = {Ranieri, E. and Brun, R. and Ochsenbein-Köble, N. and Korte, W. and Haslinger, C.},
  title = {D-dimer levels during pregnancy and postpartum: non-applicability of regularly used cut-offs for diagnosis of suspected pulmonary embolism},
  journal = {Zeitschrift für Geburtshilfe und Neonatologie},
  year = {2023},
  volume = {227},
  number = {S 01 S 01},
  pages = {e217},
  doi = {10.1055/s-0043-1776587}
}
Kostenlos starten →