EUVIMEDEUVIMED entdecken
Open Access

Biomechanical Comparison of Distal Radioulnar Joint Reconstruction Graft Preparation Techniques

Yibo Li iD, Eric Beaudry, Nader Besada, Robert Chan, Lindsey Westover

Journal of Wrist Surgery · 01.02.2024 · 13 (01) · 038-043

DOI: 10.1055/s-0043-1769909 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Wrist Surgery, erschienen am 01.02.2024. Verfasst von Yibo Li und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Surgery, Faculty of Medicine and Dentistry, University of Alberta, Edmonton, Alberta, Canada. Die Arbeit nennt 17 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Graft preparation techniques for the Adams–Berger distal radioulnar joint (DRUJ) reconstruction vary among surgeons with insufficient evidence to support any specific technique. Questions/Purposes We compared survival with cyclic loading, absolute elongation, elongation rate, and modes of failure of four graft preparation techniques.

Methods

Fifteen porcine extensor tendons were divided into three equal groups: tendon only; tendon augmented along its full length with nonlocking 2–0 FiberLoop suture spaced at 6 mm intervals; and tendon with suture at 12 mm intervals. Suture only was also tested. Samples were woven through custom radius- and ulna-simulating jigs mounted on a mechanical testing machine. Samples underwent a staircase cyclic loading protocol and were then inspected visually for the mode of failure. Survival with cyclic loading, absolute elongation, and elongation rate was compared.

Results

Average survival with cyclic loading of suture-augmented tendon was significantly higher than tendon only. All tendon groups had significantly higher survival compared with suture only. Absolute elongation was subject to variability due to initial nonlinear elongation behavior of samples. The elongation rate was significantly lower with suture compared with all tendon groups. Modes of failure included rupture of the tendon and/or suture at the simulated graft–bone interface and elongation of the entire construct without rupture.

Conclusions

In this biomechanical study, augmentation of porcine tendons with suture spaced at either 6 or 12 mm for DRUJ reconstruction significantly increased survival to a staircase cyclic loading protocol Clinical Relevance For the Adams–Berger reconstruction, tendon grafts augmented along their entire length by nonabsorbable braided suture are biomechanically superior to tendon alone.

Schlagwörter

Stichwörter der Autor:innen

biomechanical testingdistal radioulnar joint reconstructiontendon graft fixation

Autor:innen und Institutionen

  • Department of Surgery, Faculty of Medicine and Dentistry, University of Alberta, Edmonton, Alberta, Canada.
  • Department of Mechanical Engineering, Faculty of Engineering, University of Alberta, Edmonton, Alberta, Canada.
  • Department of Civil and Environmental Engineering, Faculty of Engineering, University of Alberta, Edmonton, Alberta, Canada.

ORCID-Profile: Yibo Li

Zitieren

APA

Li, Y., Beaudry, E., Besada, N., Chan, R., & Westover, L. (2024). Biomechanical Comparison of Distal Radioulnar Joint Reconstruction Graft Preparation Techniques. Journal of Wrist Surgery, 13(01), 038-043. https://doi.org/10.1055/s-0043-1769909

Vancouver

Li Y, Beaudry E, Besada N, Chan R, Westover L. Biomechanical Comparison of Distal Radioulnar Joint Reconstruction Graft Preparation Techniques. Journal of Wrist Surgery. 2024;13(01):038-043. doi:10.1055/s-0043-1769909

BibTeX
@article{Li2024,
  author = {Li, Yibo and Beaudry, Eric and Besada, Nader and Chan, Robert and Westover, Lindsey},
  title = {Biomechanical Comparison of Distal Radioulnar Joint Reconstruction Graft Preparation Techniques},
  journal = {Journal of Wrist Surgery},
  year = {2024},
  volume = {13},
  number = {01},
  pages = {038--043},
  doi = {10.1055/s-0043-1769909}
}
Kostenlos starten →