Preclinical in-vivo dosimetry of a Lu-177-ligand using a gamma probe
Nuklearmedizin - NuclearMedicine · 01.04.2023 · 62 (02) · 134-135
DOI: 10.1055/s-0043-1766293 ↗Kurz gefasst
Fachartikel in der Zeitschrift Nuklearmedizin - NuclearMedicine, erschienen am 01.04.2023. Verfasst von A. Klotsotyra und 5 weiteren Autor:innen.
Abstract (Originalsprache)
Ziel/Aim Lu-177-ligands are widely used in cancer therapy. Different ligands are studied preclinically with perspective to clinical use. We established a workflow to determine the tumor absorbed dose (TAD) in cancer xenografts of nude mice. Methodik/Methods 17 mice with implanted LNCaP xenograft tumors were treated with Lu-177-PSMA-617 (group G1: n=8 with 21.0±7.5 MBq and group G2: n=9 with 44.7±4.5 MBq). A gamma probe was used to measure counts per second (CPS) of the tumor and the body background (BG). CPS were determined for two weeks following injection. A monoexponential fit was used to determine the BG corrected time-activity curves. Effective half-life (T 1/2,eff ) of Lu-177 uptake was computed for each mouse. Tumor size (length, width, height) was measured 3 times with caliper (beginning, in the middle and at the end of gamma probe measurement period). The tumor volume (TV) was calculated as an ellipsoid. The calibration factor (CF) for the gamma probe (MBq/CPS) was determined with data of two mice. The absorbed dose-rate was tallied according to MIRD formalism using S-values for spherical tumors, after correction for time dependent ellipsoidal shape and for TV dependent absorbed fraction of full Lu-177 β spectrum. TAD was computed by integrating the dose-rate curve for each mouse. Ergebnisse/Results Average TV and T 1/2,eff were 0.19±0.11 mL and 93.8±13.5 h for G1 and 0.08±0.03 mL and 87.6±9.3 h for G2. The error of the dose-rate curves fitting was 6.7% (λ). The dominant error in dose calculation was introduced by gamma probe measurements resulting in a standard deviation of 23% for the CF. The average TAD for the first group was 0.35±0.05 Gy/MBq and 1.27±0.52 Gy/MBq for the second group. Schlussfolgerungen/Conclusions Gamma probe measurements can be reliable to estimate the tumor absorbed dose in preclinical experiments with Lu-177. Ongoing optimization of gamma probe measurements and CF determination will increase the overall accuracy of the method. Publication History Article published online: 30 March 2023 © 2023. Thieme. All rights reserved. Georg Thieme Verlag Rüdigerstraße 14, 70469 Stuttgart, Germany
Zitieren
APA
Klotsotyra, A., Arbuznikova, D., Steinacker, N., Domogalla, L. C., Eder, A. C., & Mix, M. (2023). Preclinical in-vivo dosimetry of a Lu-177-ligand using a gamma probe. Nuklearmedizin - NuclearMedicine, 62(02), 134-135. https://doi.org/10.1055/s-0043-1766293
Vancouver
Klotsotyra A, Arbuznikova D, Steinacker N, Domogalla LC, Eder AC, Mix M. Preclinical in-vivo dosimetry of a Lu-177-ligand using a gamma probe. Nuklearmedizin - NuclearMedicine. 2023;62(02):134-135. doi:10.1055/s-0043-1766293
BibTeX
@article{Klotsotyra2023,
author = {Klotsotyra, A. and Arbuznikova, D. and Steinacker, N. and Domogalla, L. C. and Eder, A. C. and Mix, M.},
title = {Preclinical in-vivo dosimetry of a Lu-177-ligand using a gamma probe},
journal = {Nuklearmedizin - NuclearMedicine},
year = {2023},
volume = {62},
number = {02},
pages = {134--135},
doi = {10.1055/s-0043-1766293}
}
EUVIMED