EUVIMEDEUVIMED entdecken
Crossref

Real-Time Computer-Aided Polyp and Adenoma Detection During Screening Colonoscopy In Expert And Non-Expert Endoscopists: A Single Center Study

C. Robles-Medranda, C. Cifuentes-Gordillo, M. Arevalo-Mora, M. Egas-Izquierdo, M. Puga-Tejada, D. Cunto, J. Alcivar-Vasquez, R. Del Valle, H. Alvarado-Escobar, H. Pitanga-Lukashok, J. Baquerizo-Burgos, D. Tabacelia

Endoscopy · 01.04.2023 · 55 (S 02 S 02) · S232-S233

DOI: 10.1055/s-0043-1765620 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Endoscopy, erschienen am 01.04.2023. Verfasst von C. Robles-Medranda und 11 weiteren Autor:innen. Die Arbeit nennt 6 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aims

To evaluate the real-world effectiveness of an AI-assisted colonoscopy (AI-VCC) and compare the results among experts and non-experts endoscopists (Fig. 1).

Methods

Consecutive patients ≥45 years old who underwent VCC (11/2020-03/2021). First, a standard HD-VCC was performed. Then, an AI-VCC was performed by a second operator blinded to previous findings. Adenoma detection rate (ADR) was a quality indicator of the procedure. The polyp detection rate (PDR), and the adenoma and polyp miss rates (AMR and PMR, respectively) were also calculated. The results were compared between experts and non-experts endoscopists. NCT04915833 [ 1 ] [ 2 ] [ 3 ] [ 4 ] [ 5 ] [ 6 ] (Fig. 2).

Results

115 patients were included. 58/115 (50.4%) had a total of 205 polyps/adenoma, with a PDR and ADR of 132/205 (64.3%) and 73/205 (35.6%) with VCC, respectively: 19/205 (9.3%) NICE II, 7/205 (3.4%) >10 mm. With AI-assistance, the ADR and PDR increased from 16.5% to 18.2% and from 50.4% to 60%, respectively. The ADR increased from 10.8% to 16.2% in the junior group with the AI-VCC. No difference in ADR was observed in the senior cohort ([ Table 1 ]). PMR was 43.13%, AMR was 5.19%. Sensitivity among different colon segments ranged from 56.25% (rectum) to 78.26% (ascending colon). Capability of AI for appropriate polyp and adenoma presence discharging (negative predictive value, NPV) ranged from 61.54% (sigmoid) to 89.09% (cecum). Lower rates for specificity (8.42-49.49%) and PPV (9.89-19.78%) were observed due to high false positives. ([ Table 2 ]). Table 1 ADR and PDR during HD-VCC and AI-VCC in senior and junior endoscopists. Table 2 Overall accuracy of the Artificial Intelligence assisted polyp detector for polyp/adenoma detection.

Conclusions

Junior endoscopists benefit from the AI-assisted polyp detector during screening colonoscopy as it helps them achieve an ADR comparable to that of senior endoscopists. Publication History Article published online: 14 April 2023 © 2023. European Society of Gastrointestinal Endoscopy. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany

Zitieren

APA

Robles-Medranda, C., Cifuentes-Gordillo, C., Arevalo-Mora, M., Egas-Izquierdo, M., Puga-Tejada, M., Cunto, D., Alcivar-Vasquez, J., Valle, R. D., Alvarado-Escobar, H., Pitanga-Lukashok, H., Baquerizo-Burgos, J., & Tabacelia, D. (2023). Real-Time Computer-Aided Polyp and Adenoma Detection During Screening Colonoscopy In Expert And Non-Expert Endoscopists: A Single Center Study. Endoscopy, 55(S 02 S 02), S232-S233. https://doi.org/10.1055/s-0043-1765620

Vancouver

Robles-Medranda C, Cifuentes-Gordillo C, Arevalo-Mora M, Egas-Izquierdo M, Puga-Tejada M, Cunto D, et al. Real-Time Computer-Aided Polyp and Adenoma Detection During Screening Colonoscopy In Expert And Non-Expert Endoscopists: A Single Center Study. Endoscopy. 2023;55(S 02 S 02):S232-S233. doi:10.1055/s-0043-1765620

BibTeX
@article{RoblesMedranda2023,
  author = {Robles-Medranda, C. and Cifuentes-Gordillo, C. and Arevalo-Mora, M. and Egas-Izquierdo, M. and Puga-Tejada, M. and Cunto, D. and Alcivar-Vasquez, J. and Valle, R. Del and Alvarado-Escobar, H. and Pitanga-Lukashok, H. and Baquerizo-Burgos, J. and Tabacelia, D.},
  title = {Real-Time Computer-Aided Polyp and Adenoma Detection During Screening Colonoscopy In Expert And Non-Expert Endoscopists: A Single Center Study},
  journal = {Endoscopy},
  year = {2023},
  volume = {55},
  number = {S 02 S 02},
  pages = {S232--S233},
  doi = {10.1055/s-0043-1765620}
}
Kostenlos starten →