EUVIMEDEUVIMED entdecken
Crossref

Comparison of tissue adequacy between wet suction versus slow-pull technique in endoscopic ultrasound-guided fine needle biopsy in solid lesions: a randomized cross-over trial

J. Samanta, R. Thakur, M. Rohilla, S. S. Nagaraj, C. Tandup, H. Mandavdhare, D. Kumar, V. Gupta, R. Srinivasan, S. K. Sinha

Endoscopy · 01.04.2023 · 55 (S 02 S 02) · S158-S159

DOI: 10.1055/s-0043-1765401 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Endoscopy, erschienen am 01.04.2023. Verfasst von J. Samanta und 9 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aims

Modifications to improve tissue yield in endoscopic ultrasound-guided fine needle biopsy (EUS-FNB) has been explored. Conflicting data exist for wet suction (WS) versus slow stylet pull (SP) for “pure” solid lesions and thus, we planned this study.

Methods

This was a single tertiary care center, randomized, single-blind, cross-over trial including patients with “pure” solid lesions (lymph node excluded). Two passes each utilizing WS or SP in a randomized order were performed. Both cytological smears as well as cell block tissue qualities were assessed. The primary aim was tissue core yield. Secondary endpoints were technical success, specimen adequacy, cellularity, and blood contamination rates.

Results

Overall, 170 samples obtained from 85 patients (45 males; 52.9%) were included in the analysis, of which 114 (67.1%) were pancreatic lesions. Primary outcome of tissue core > 550 µm was similar (60% vs 54.1%;p=0.44). Technical success and specimen adequacy were similar in both the arms. For cytological smear quality, grade 3 cellularity was similar in the two arms (p=0.11). However, blood contamination score showed a higher trend in the WS compared to SP (p=0.05) in the overall cohort and significantly higher (p=0.047) in the pancreatic lesion sub-group. For cell block tissue quality, grade 4 cellularity, the cellularity score as well as blood contamination scores were similar in the two arms.

Conclusions

Overall, the SP and WS techniques performed comparably for solid lesions in terms of tissue integrity, cellularity, and specimen adequacy. Cytology smears showed higher blood contamination using WS, particularly for pancreatic lesions. (Trial Reg. number: CTRI/2022/02/040100) ([ Fig. 1 ]). Fig. 1 Outcome parameters comparing the tissue characteristics between the wet suction and slow-stylet pull techniques of EUS-guided FNB Publication History Article published online: 14 April 2023 © 2023. European Society of Gastrointestinal Endoscopy. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany

Zitieren

APA

Samanta, J., Thakur, R., Rohilla, M., Nagaraj, S. S., Tandup, C., Mandavdhare, H., Kumar, D., Gupta, V., Srinivasan, R., & Sinha, S. K. (2023). Comparison of tissue adequacy between wet suction versus slow-pull technique in endoscopic ultrasound-guided fine needle biopsy in solid lesions: a randomized cross-over trial. Endoscopy, 55(S 02 S 02), S158-S159. https://doi.org/10.1055/s-0043-1765401

Vancouver

Samanta J, Thakur R, Rohilla M, Nagaraj SS, Tandup C, Mandavdhare H, et al. Comparison of tissue adequacy between wet suction versus slow-pull technique in endoscopic ultrasound-guided fine needle biopsy in solid lesions: a randomized cross-over trial. Endoscopy. 2023;55(S 02 S 02):S158-S159. doi:10.1055/s-0043-1765401

BibTeX
@article{Samanta2023,
  author = {Samanta, J. and Thakur, R. and Rohilla, M. and Nagaraj, S. S. and Tandup, C. and Mandavdhare, H. and Kumar, D. and Gupta, V. and Srinivasan, R. and Sinha, S. K.},
  title = {Comparison of tissue adequacy between wet suction versus slow-pull technique in endoscopic ultrasound-guided fine needle biopsy in solid lesions: a randomized cross-over trial},
  journal = {Endoscopy},
  year = {2023},
  volume = {55},
  number = {S 02 S 02},
  pages = {S158--S159},
  doi = {10.1055/s-0043-1765401}
}
Kostenlos starten →