HOSPA study: multi-center prospective evaluation of the new Hot-Spaxus lumen apposing metal stent (LAMS)

A. Martinez-Ortega, I. Latras-Cortés, F. J. García-Alonso, J. R. Aparicio, V. Sanchiz-Soler, J. B. Gornals, B. Martínez-Moreno, A. Sumalla-Garcia, J. C. Subtil-Iñigo, C. De La Serna Higuera, M. Perez-Miranda

Endoscopy · 01.04.2023 · 55 (S 02 S 02) · S42-S43

DOI: 10.1055/s-0043-1765099 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Endoscopy, erschienen am 01.04.2023. Verfasst von A. Martinez-Ortega und 10 weiteren Autor:innen. Die Arbeit nennt 3 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aims

LAMS have revolutionized therapeutic EUS. The gold-standard LAMS (Hot-Axios [BostonScientific]) has been challenged by newer models offering cost advantages (Hot-Spaxus [TaewoongMedical]). Prospective evaluation of newer LAMS would help clarify its role. Aim: to evaluate technical success, short-term clinical success, and adverse events (AEs) of Hot-Spaxus in pancreatic fluid collection (PFC) or gallbladder (GB) drainage. 2ary aim: operators’ subjective Hot-Spaxus assessment [ 1 ] [ 2 ] [ 3 ].

Methods

57 consecutive patients from five tertiary centers with indications for EUS-LAMS were screened between July-Sept 2022 ( [ Fig. 1 ]). Only expert endoscopists (>50 LAMS) were involved. Objective procedure metrics and a standardized 9-item subjective evaluation were prospectively collected and analyzed. Fig. 1 Patients flow-chart Results 12 patients met inclusion criteria [8(66, %) female; 78(14.26) years]. (Table 1) Cholecystitis was the dominant indication (58,3%). LAMS diameter was 16-20mm in 75%. Technical success: 11/12 (91,7%), 1 LAMS dislodgement. Medium (SD) target size: 52.75 (49.5) mm; distance to target: 7.3 (3.7) mm. Median (SD) LAMS deployment time: 209,4 (127,96) seconds. AEs: 1/12 (8,3%), moderate bleeding. Short-term clinical success: 10/11 (90.9%). Subjective evaluation data is shown in [ Fig. 2 ] Fig. 2 Subjective evaluation Conclusions Hot-Spaxus technical success, short-term clinical success and AEs in PFC/ GB drainage appear similar to Hot-Axios. Subjective operator assessment however favors Hot-Axios for ease of penetration, position control and LAMS deployment system use (Fig. 3). Table 1.

Results

Table 3 Publication History Article published online: 14 April 2023 © 2023. European Society of Gastrointestinal Endoscopy. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany

Zitieren

APA

Martinez-Ortega, A., Latras-Cortés, I., García-Alonso, F. J., Aparicio, J. R., Sanchiz-Soler, V., Gornals, J. B., Martínez-Moreno, B., Sumalla-Garcia, A., Subtil-Iñigo, J. C., Higuera, C. D. L. S., & Perez-Miranda, M. (2023). HOSPA study: multi-center prospective evaluation of the new Hot-Spaxus lumen apposing metal stent (LAMS). Endoscopy, 55(S 02 S 02), S42-S43. https://doi.org/10.1055/s-0043-1765099

Vancouver

Martinez-Ortega A, Latras-Cortés I, García-Alonso FJ, Aparicio JR, Sanchiz-Soler V, Gornals JB, et al. HOSPA study: multi-center prospective evaluation of the new Hot-Spaxus lumen apposing metal stent (LAMS). Endoscopy. 2023;55(S 02 S 02):S42-S43. doi:10.1055/s-0043-1765099

BibTeX
@article{MartinezOrtega2023,
  author = {Martinez-Ortega, A. and Latras-Cortés, I. and García-Alonso, F. J. and Aparicio, J. R. and Sanchiz-Soler, V. and Gornals, J. B. and Martínez-Moreno, B. and Sumalla-Garcia, A. and Subtil-Iñigo, J. C. and Higuera, C. De La Serna and Perez-Miranda, M.},
  title = {HOSPA study: multi-center prospective evaluation of the new Hot-Spaxus lumen apposing metal stent (LAMS)},
  journal = {Endoscopy},
  year = {2023},
  volume = {55},
  number = {S 02 S 02},
  pages = {S42--S43},
  doi = {10.1055/s-0043-1765099}
}
Kostenlos starten →