Veno-Arterial Partial Pressure of Carbon Dioxide Difference as a Metric of Systemic Oxygen Delivery: Insights from a Correlative Meta-Analysis
Journal of Pediatric Intensive Care · 01.12.2024 · 13 (04) · 372-378
DOI: 10.1055/s-0042-1743501 ↗Kurz gefasst
Metaanalyse in der Zeitschrift Journal of Pediatric Intensive Care, erschienen am 01.12.2024. Verfasst von Rohit S Loomba und 5 weiteren Autor:innen. Beteiligte Einrichtung: Division of Cardiology, Advocate Children's Hospital, Chicago, Illinois, United States. Die Arbeit nennt 26 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
The assessment of cardiac output and adequacy of systemic oxygen delivery in children after cardiac surgery require the use of an aggregate of hemodynamic monitors and blood tests. There are previously published data regarding the utility of the veno-arterial partial pressure of carbon dioxide difference (AVDco2) to help with this. This study pooled data on the correlation of AVDco2 with other metrics of cardiac output and systemic oxygen delivery such as arteriovenous oxygen saturation difference, venous saturation, and serum lactate. A systematic review of the literature was done to identify studies analyzing the correlation of AVDco2 with other hemodynamic and laboratory values. Data were extracted, and correlation coefficients were pooled for each specific comparison to create a point estimate for the overall correlation. A total of four studies with 350 patients and 809 paired blood gases were pooled. Adequate data were available to assess the correlation of AVDco2 with arteriovenous oxygen saturation difference, venous saturation, and serum lactate. There was a significant, moderate correlation with arteriovenous oxygen saturation difference and venous saturation. A significant, weak correlation with serum lactate was found. The AVDco2 has significant, moderate correlations with other metrics of the adequacy of systemic oxygen delivery such as arteriovenous oxygen saturation difference and venous saturation. There was a significant but only weak correlation with serum lactate. AVDco2 may be complementary to assess the adequacy of cardiac output and systemic oxygen delivery.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Division of Cardiology, Advocate Children's Hospital, Chicago, Illinois, United States.
- Department of Pediatrics, Chicago Medical School/Rosalind Franklin University of Medicine and Science, Chicago, Illinois, United States.
- Section of Critical Care Medicine and Cardiology, Texas Children's Hospital, Houston, Texas, United States.
- Department of Pediatrics, Baylor College of Medicine, Houston, Texas, United States.
- Tecnologico de Monterrey, School of Medicine and Health Sciences, Monterrey, Nuevo Leon, Mexico.
ORCID-Profile: Rohit S Loomba, Juan S Farias, Saul Flores, Enrique G Villarreal
Zitieren
APA
Loomba, R. S., Farias, J. S., Savorgnan, F., Acosta, S., Flores, S., & Villarreal, E. G. (2024). Veno-Arterial Partial Pressure of Carbon Dioxide Difference as a Metric of Systemic Oxygen Delivery: Insights from a Correlative Meta-Analysis. Journal of Pediatric Intensive Care, 13(04), 372-378. https://doi.org/10.1055/s-0042-1743501
Vancouver
Loomba RS, Farias JS, Savorgnan F, Acosta S, Flores S, Villarreal EG. Veno-Arterial Partial Pressure of Carbon Dioxide Difference as a Metric of Systemic Oxygen Delivery: Insights from a Correlative Meta-Analysis. Journal of Pediatric Intensive Care. 2024;13(04):372-378. doi:10.1055/s-0042-1743501
BibTeX
@article{Loomba2024,
author = {Loomba, Rohit S and Farias, Juan S and Savorgnan, Fabio and Acosta, Sebastian and Flores, Saul and Villarreal, Enrique G},
title = {Veno-Arterial Partial Pressure of Carbon Dioxide Difference as a Metric of Systemic Oxygen Delivery: Insights from a Correlative Meta-Analysis},
journal = {Journal of Pediatric Intensive Care},
year = {2024},
volume = {13},
number = {04},
pages = {372--378},
doi = {10.1055/s-0042-1743501}
}