EUVIMEDEUVIMED entdecken
Crossref

Radiation Exposure in the Neonatal Intensive Care Unit in Newborns and Staff

Salih Cagri Cakir iD, Bayram Ali Dorum iD, Nilgun Koksal, Hilal Ozkan, Zeynep Yazici, Mufit Parlak, Nadide Basak Gulleroglu

American Journal of Perinatology · 01.07.2023 · 40 (10) · 1106-1111

DOI: 10.1055/s-0041-1733779 ↗

Kurz gefasst

Fachartikel in der Zeitschrift American Journal of Perinatology, erschienen am 01.07.2023. Verfasst von Salih Cagri Cakir und 6 weiteren Autor:innen. Beteiligte Einrichtung: Division of Neonatology, Department of Pediatrics, Bursa Uludag University Faculty of Medicine, Gorukle, Bursa, Turkey. Hauptthemen laut MEDLINE: Intensive Care Units, Neonatal, Radiation Exposure. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 23 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

Portable X-rays remain one of the most frequently used diagnostic procedures in neonatal intensive care units (NICU). Premature infants are more sensitive to radiation-induced harmful effects. Dangers from diagnostic radiation can occur with stochastic effects. We aimed to determine the radiation exposure in premature infants and staff and determine the scattering during X-ray examinations in the NICU. Study Design In this prospective study, dosimeters were placed on premature infants who were ≤1,250 g at birth and ≤30 weeks of gestational age who stayed in the NICU for at least 4 weeks. The doses were measured at each X-ray examination during their stay. The measurements of the nurses and the doctors in the NICU were also performed with dosimeters over the 1-month period. Other dosimeters were placed in certain areas outside the incubator and the results were obtained after 1 month.

Results

The mean radiation exposure of the 10 premature infants, monitored with dosimeters, was 3.65 ± 2.44 mGy. The mean skin dose of the six staff was 0.087 ± 0.0998 mSV. The mean scattered dose was 67.9 ± 26.5 µGy.

Conclusion

Relatively high exposures were observed in 90% of the patients and two staff. The radiation exposure levels of premature infants and staff may need to be monitored continuously. Key Points

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Intensive Care Units, NeonatalRadiation ExposureInfantInfant, NewbornHumansProspective StudiesInfant, PrematureRadiography

Autor:innen und Institutionen

  • Division of Neonatology, Department of Pediatrics, Bursa Uludag University Faculty of Medicine, Gorukle, Bursa, Turkey.
  • Department of Radiology, Bursa Uludag University Faculty of Medicine, Bursa, Turkey.

ORCID-Profile: Salih Cagri Cakir, Bayram Ali Dorum

Zitieren

APA

Cakir, S. C., Dorum, B. A., Koksal, N., Ozkan, H., Yazici, Z., Parlak, M., & Gulleroglu, N. B. (2023). Radiation Exposure in the Neonatal Intensive Care Unit in Newborns and Staff. American Journal of Perinatology, 40(10), 1106-1111. https://doi.org/10.1055/s-0041-1733779

Vancouver

Cakir SC, Dorum BA, Koksal N, Ozkan H, Yazici Z, Parlak M, et al. Radiation Exposure in the Neonatal Intensive Care Unit in Newborns and Staff. American Journal of Perinatology. 2023;40(10):1106-1111. doi:10.1055/s-0041-1733779

BibTeX
@article{Cakir2023,
  author = {Cakir, Salih Cagri and Dorum, Bayram Ali and Koksal, Nilgun and Ozkan, Hilal and Yazici, Zeynep and Parlak, Mufit and Gulleroglu, Nadide Basak},
  title = {Radiation Exposure in the Neonatal Intensive Care Unit in Newborns and Staff},
  journal = {American Journal of Perinatology},
  year = {2023},
  volume = {40},
  number = {10},
  pages = {1106--1111},
  doi = {10.1055/s-0041-1733779}
}
Kostenlos starten →