Artificial Intelligence-Assisted Optical Diagnosis Does Not Improve Colorectal Polyp Characterization: A Pooled Analysis of Two Randomized Trials
Endoscopy International Open · 22.11.2026
DOI: 10.1055/a-3011-6534 ↗Kurz gefasst
Fachartikel in der Zeitschrift Endoscopy International Open, erschienen am 22.11.2026. Verfasst von Nikolaos Papachrysos und 12 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: regional R&D funding program, Gothenburg Society of Medicine, Bengt Ihre Research Fellowship.
Abstract (Originalsprache)
Background and study aims Computer-aided diagnosis (CADx) is intended to improve real-time characterization of colorectal polyps. This study evaluates whether CADx-assisted colonoscopy improves the accuracy of polyp classification compared with conventional colonoscopy (CC). Patients and methods We pooled CADx-relevant data from two randomized trials evaluating CAD EYE and GI Genius. Participants were randomized 1:1 to CADx-assisted colonoscopy or conventional colonoscopy, with no AI active at any stage in the control group. The primary outcome was per-polyp accuracy of the endoscopist’s optical diagnosis against histopathology.
Results
684 patients with 1,154 lesion records were included, 795 lesions (451 CADx-assisted, 344 CC) entering the primary analysis. Overall accuracy did not differ between CADx-assisted endoscopy and CC (76.9%, 95% CI 72.8–80.6 vs 79.7%, 75.1–83.6). CC showed higher sensitivity than CADx-assisted endoscopy (88.9%, 84.2–92.3 vs 80.6%, 75.9–84.6; adjusted odds ratio 0.50, 0.28–0.91), with a similar trend for negative predictive value (NPV) (71.7% vs 58.9%). The sensitivity difference was confined to experienced and expert endoscopists (89.4% vs 80.2%) and absent among trainees and newly qualified specialists (p for interaction 0.248). For 0–4 mm polyps, NPV was 71.4% with CC and 54.2% with CADx; for 0–4 mm rectosigmoid lesions, the population to which the guideline threshold applies, it was 92.9% and 66.7%. At least one adenoma was optically classified as non-neoplastic in 25.9% of CADx participants versus 13.0% of CC participants (p=0.003).
Conclusions
CADx assistance did not improve polyp characterization, and sensitivity for adenomatous lesions was lower when a prediction was displayed. These findings indicate that CADx requires refinement before it can support optical management.
Förderung
- regional R&D funding program
- Gothenburg Society of Medicine
- Bengt Ihre Research Fellowship
- FoU program for healthcare areas covered by NHV
- ALFGBG
Zitieren
APA
Papachrysos, N., Hammer, H. L., Eriksson, A. S., Krona, L., Köster, M., Rauch, B., Sondén, R. S., Barth, S., Hedenstrom, P., Lindkvist, B., Trinh, J., Lange, T. D., & Varkey, J. (2026). Artificial Intelligence-Assisted Optical Diagnosis Does Not Improve Colorectal Polyp Characterization: A Pooled Analysis of Two Randomized Trials. Endoscopy International Open. https://doi.org/10.1055/a-3011-6534
Vancouver
Papachrysos N, Hammer HL, Eriksson AS, Krona L, Köster M, Rauch B, et al. Artificial Intelligence-Assisted Optical Diagnosis Does Not Improve Colorectal Polyp Characterization: A Pooled Analysis of Two Randomized Trials. Endoscopy International Open. 2026. doi:10.1055/a-3011-6534
BibTeX
@article{Papachrysos2026,
author = {Papachrysos, Nikolaos and Hammer, Hugo L. and Eriksson, Anders S and Krona, Linda and Köster, Michael and Rauch, Bente and Sondén, Rasmus Söderström and Barth, Stephanie and Hedenstrom, Per and Lindkvist, Björn and Trinh, Jonny and Lange, Thomas de and Varkey, Jonas},
title = {Artificial Intelligence-Assisted Optical Diagnosis Does Not Improve Colorectal Polyp Characterization: A Pooled Analysis of Two Randomized Trials},
journal = {Endoscopy International Open},
year = {2026},
doi = {10.1055/a-3011-6534}
}
EUVIMED