Port-Hopping Technique for Robotic Mediastinal Lymph Node Dissection
The Thoracic and Cardiovascular Surgeon · 20.11.2026
DOI: 10.1055/a-3001-3467 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Thoracic and Cardiovascular Surgeon, online erschienen am 20.11.2026. Verfasst von Junichi Murakami und 2 weiteren Autor:innen. Die Arbeit nennt 5 Literaturangaben.
Abstract (Originalsprache)
Standard port configurations for robotic-assisted thoracic surgery lobectomy often restrict instrument angles and limit visualization during mediastinal lymph node dissection. We describe “port-hopping,” in which the scope and instruments are exchanged among the docked robotic arms without moving ports or re-docking. In this maneuver, performed after lobectomy or before bronchial transection for subcarinal dissection, the third-arm role moves to the ventral-most arm, while the other roles shift one port dorsally. A vessel sealer holding a gauze pledget provides planar retraction for en bloc dissection. Port-hopping allows the console surgeon to control exposure without assistant-dependent retraction and is simple and feasible.
Zitieren
APA
Murakami, J., Yoshimine, S., & Tanaka, T. (2026). Port-Hopping Technique for Robotic Mediastinal Lymph Node Dissection. The Thoracic and Cardiovascular Surgeon. https://doi.org/10.1055/a-3001-3467
Vancouver
Murakami J, Yoshimine S, Tanaka T. Port-Hopping Technique for Robotic Mediastinal Lymph Node Dissection. The Thoracic and Cardiovascular Surgeon. 2026. doi:10.1055/a-3001-3467
BibTeX
@article{Murakami2026,
author = {Murakami, Junichi and Yoshimine, Sota and Tanaka, Toshiki},
title = {Port-Hopping Technique for Robotic Mediastinal Lymph Node Dissection},
journal = {The Thoracic and Cardiovascular Surgeon},
year = {2026},
doi = {10.1055/a-3001-3467}
}