Experiences Using a 1.7 mm Locking Bone Plate System for Stabilization of Appendicular Fractures in Dogs and Cats
Veterinary and Comparative Orthopaedics and Traumatology · 15.11.2026
DOI: 10.1055/a-2993-2622 ↗Kurz gefasst
Fachartikel in der Zeitschrift Veterinary and Comparative Orthopaedics and Traumatology, erschienen am 15.11.2026. Verfasst von Kian Scott Martin und 1 weiteren Autor:innen.
Abstract (Originalsprache)
Objective
To retrospectively evaluate the stabilization of appendicular fractures using the Fixin 1.7 mm locking plate system in dogs and cats. Study Design A review of patient medical records with traumatic appendicular fractures stabilized with the Fixin 1.7 mm locking plate was performed. Fractures were excluded due to lack of follow-up radiographs, prophylactic plating, or the use of additional plates. Data pertaining to the signalment, fracture classification, implants, evidence of radiographic healing, and limb function were recorded. Stabilization included both minimally invasive plate osteosynthesis (MIPO) and open reduction and internal fixation (ORIF) methods. Outcomes were determined from clinical and radiographic follow-ups.
Results
One hundred out of 133 evaluated fractures met inclusion criteria. Median age and weight were 3 (IQR 1–6) years and 3.46 (IQR 2.5–4.78) kg. Complete healing occurred in 29/37 (78%) MIPO and 48/63 (76%) ORIF cases, for a combined outcome of 77/100 (77%). Complications occurred in 7/37 (19%) fractures repaired via MIPO and 8/63 (13%) fractures repaired via ORIF, with an overall complication rate of 15/100 (15%).
Conclusion
Results suggest the Fixin 1.7 mm system provides acceptable outcomes comparable to existing micro-locking systems in appropriately selected cases.
Zitieren
APA
Martin, K. S., & Johnson, M. D. (2026). Experiences Using a 1.7 mm Locking Bone Plate System for Stabilization of Appendicular Fractures in Dogs and Cats. Veterinary and Comparative Orthopaedics and Traumatology. https://doi.org/10.1055/a-2993-2622
Vancouver
Martin KS, Johnson MD. Experiences Using a 1.7 mm Locking Bone Plate System for Stabilization of Appendicular Fractures in Dogs and Cats. Veterinary and Comparative Orthopaedics and Traumatology. 2026. doi:10.1055/a-2993-2622
BibTeX
@article{Martin2026,
author = {Martin, Kian Scott and Johnson, Matthew D.},
title = {Experiences Using a 1.7 mm Locking Bone Plate System for Stabilization of Appendicular Fractures in Dogs and Cats},
journal = {Veterinary and Comparative Orthopaedics and Traumatology},
year = {2026},
doi = {10.1055/a-2993-2622}
}
EUVIMED