Objective Assessment of Endoscopic Tip Control Using Artificial Intelligence and Video Motion Analysis: A Proof-of-Concept Study

Objektive Bewertung der Endoskop-Spitzenkontrolle mit künstlicher Intelligenz und Video-Bewegungsanalyse: Proof-of-Concept-Studie

Tamas Tornai, Michele Montori, Maria Eva Argenziano, Jelle Vanhaeverbeke, Pieter Jan Poortmans, Andrea Sorge, Kenzo Milleville, Steven Verstockt, Lynn K. Debels, Roland Valori, John Anderson, Lobke Desomer und 1 weitere

Endoscopy International Open · 03.11.2026 · 14 (CP)

DOI: 10.1055/a-2979-6508 ↗

Auf einen Blick

Bei 13 Endoskop:innen wurde eine KI-gestützte Videoanalyse zur objektiven Quantifizierung der Spitzenkontrolle geprüft. Das Modell näherte sich den subjektiven Bewertungen gut an.

Fragestellung

Lässt sich Endoskop-Spitzenkontrolle mit einer KI- und Bewegungsanalyse objektiv quantifizieren?

Methode

Single-Center Proof-of-Concept-Studie mit 13 Endoskop:innen; standardisierte Aufgaben am Ham-Modell; KI-Klassifikation von on- und off-target sowie Optical-Flow-Analyse; interne Kreuzvalidierung.

Ergebnisse

Die Übereinstimmung der subjektiven Bewertungen war moderat bis gut (ICC 0,74; 95 %-KI 0,60–0,87). Drei Prädiktoren dominierten: mehr off-target Zeit, mehr Bewegungsvolatilität und größere Volatilitätsspitzen.

Einschränkungen

Single-Center-Studie; internes Validierungsdesign.

Schlussfolgerung der Autor:innen

Die Kombination aus KI-Labeling der Aufgabenbeteiligung und Optical-Flow-Analyse approximierte die panelbewertete Spitzenkontrolle. Das Konzept könnte eine skalierbare, standardisierte Bewertung ermöglichen.

Kernaussagen

  • 13 Endoskop:innen bearbeiteten standardisierte Aufgaben am Ham-Modell
  • ICC der subjektiven Tip-Control-Bewertung: 0,74
  • Finales Modell: MAE 12,2; RMSE 15,0

Deutsche Zusammenfassung: KI-gestützt aus dem Original-Abstract erstellt; alle Zahlen wurden automatisch mit dem Original abgeglichen. Maßgeblich ist der Original-Abstract.

Kurz gefasst

Fachartikel in der Zeitschrift Endoscopy International Open, online erschienen am 03.11.2026. Verfasst von Tamas Tornai und 12 weiteren Autor:innen. Die Arbeit nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Stichting Tegen Kanker.

Auf einen BlickAbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background and Aims Precise control of the endoscope's distal tip is a core visuomotor competence underpinning procedural safety and success. Despite its importance, objective assessment of tip control remains limited by reliance on subjective human judgment. We aimed to develop and internally validate a computer-vision pipeline, combining an artificial intelligence (AI)-based classifier of on- and off-target task engagement with optical-flow motion analysis, for objective quantification of endoscopic tip control within a standardised training model.

Methods

Thirteen endoscopists of varying experience performed standardised snare-tip soft coagulation tasks on stencil-imprinted ham models. Procedures were analysed using a computer-vision pipeline combining AI-based on-target/off-target classification with optical-flow motion analysis. Blinded raters assigned subjective tip control scores (0–100%). Associations between pipeline-derived motion metrics and scores were examined using generalised linear mixed models, followed by model selection and internal cross-validation.

Results

Inter-rater reliability of subjective tip control scores was moderate-to-good (ICC[A, k̂ = 3]: 0.74 [95% CI 0.60–0.87]). Multivariable analyses consistently identified three key predictors of tip control. Higher off-target time was associated with a 10.1 percentage-point reduction in tip control scores (95% CI −13.7 to −6.5), greater motion volatility with a 14.7-point reduction (95% CI −22.2 to −7.3), whereas larger volatility peaks were associated with a 12.3-point increase in scores (95% CI 4.2–20.5). The final model demonstrated good out-of-sample performance (mean absolute error: 12.2, root mean squared error: 15.0).

Conclusion

In this single-centre proof-of-concept study, AI-based labelling of task engagement combined with optical-flow motion analysis approximated panel rated tip control, which was characterised by sustained spatial accuracy, global motion stability, and well-timed corrective adjustments. This concept could support the development of a scalable and standardised tool for evaluating endoscopic tip control.

Förderung

  • Stichting Tegen Kanker

Zitieren

APA

Tornai, T., Montori, M., Argenziano, M. E., Vanhaeverbeke, J., Poortmans, P. J., Sorge, A., Milleville, K., Verstockt, S., Debels, L. K., Valori, R., Anderson, J., Desomer, L., & Tate, D. J. (2026). Objective Assessment of Endoscopic Tip Control Using Artificial Intelligence and Video Motion Analysis: A Proof-of-Concept Study. Endoscopy International Open, 14(CP). https://doi.org/10.1055/a-2979-6508

Vancouver

Tornai T, Montori M, Argenziano ME, Vanhaeverbeke J, Poortmans PJ, Sorge A, et al. Objective Assessment of Endoscopic Tip Control Using Artificial Intelligence and Video Motion Analysis: A Proof-of-Concept Study. Endoscopy International Open. 2026;14(CP). doi:10.1055/a-2979-6508

BibTeX
@article{Tornai2026,