Narrow-Band Imaging with Acetic Acid Enhancement for Real-Time Optical Diagnosis of Colonic Polyps: A Retrospective Video-Review Study
Endoscopy International Open · 18.11.2026 · 14 (CP)
DOI: 10.1055/a-2976-6823 ↗Kurz gefasst
Fachartikel in der Zeitschrift Endoscopy International Open, online erschienen am 18.11.2026. Verfasst von Mei Yang und 11 weiteren Autor:innen. Die Arbeit nennt 18 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Medical Research Project of Chengdu Municipal Health Commission.
Abstract (Originalsprache)
Approximately 40–60% of colorectal polyps detected during colonoscopy are nonadenomatous and do not require resection. Accurate, real-time optical diagnosis could reduce unnecessary polypectomy. Whether acetic acid enhancement improves nonmagnified narrow-band imaging (NBI) accuracy for colonic polyps remains unclear. This study aimed to evaluate the diagnostic performance of NBI combined with acetic acid enhancement (A-NBI) compared with NBI alone for real-time optical diagnosis of colonic polyps using a retrospective video-review design. This single-center, retrospective diagnostic study was conducted at the Third People’s Hospital of Chengdu, China. Colonoscopy videos recorded between June 2022 and June 2023 were retrospectively collected. Polyps had been examined using either NBI or A-NBI (3% acetic acid) during the index procedures. Recorded video segments were independently reviewed by four endoscopists (two junior and two expert endoscopists), blinded to histopathological results. Of the 350 polyps identified, 333 met inclusion criteria. Diagnostic accuracy, sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) for differentiating adenomatous from nonadenomatous polyps were calculated, with histopathology as the reference standard. Among the 333 polyps analyzed (median size 6 mm; range 3–20 mm), 244 (73.3%) were adenomas, 74 (22.2%) were hyperplastic polyps, and 15 (4.5%) were sessile serrated lesions. Overall diagnostic accuracy was 86.36% for A-NBI and 80.89% for NBI (P = 0.18). For diminutive polyps (≤ 5 mm), A-NBI demonstrated significantly higher specificity (72.22 vs. 30.00%; P = 0.05) and NPV (76.47 vs. 27.27%; P = 0.02). For polyps ≥10 mm, A-NBI achieved 100% accuracy compared with 72.73% for NBI (P = 0.049). In multireviewer validation, A-NBI significantly improved diagnostic accuracy across all four endoscopists (all P < 0.05). A-NBI demonstrated nominally higher overall diagnostic accuracy than NBI alone for colonic polyps, with significant improvements in specificity and NPV for diminutive polyps and in accuracy for larger polyps. These findings support acetic acid as a practical, safe adjunct to nonmagnified NBI colonoscopy, warranting prospective multicenter validation.
Förderung
- Medical Research Project of Chengdu Municipal Health Commission
Zitieren
APA
Yang, M., Wang, Y., Shi, L., Tang, Z., Xue, M., Luo, T., Shan, J., Jiang, L., Chen, T., Li, J., Chen, Y., & Sun, X. (2026). Narrow-Band Imaging with Acetic Acid Enhancement for Real-Time Optical Diagnosis of Colonic Polyps: A Retrospective Video-Review Study. Endoscopy International Open, 14(CP). https://doi.org/10.1055/a-2976-6823
Vancouver
Yang M, Wang Y, Shi L, Tang Z, Xue M, Luo T, et al. Narrow-Band Imaging with Acetic Acid Enhancement for Real-Time Optical Diagnosis of Colonic Polyps: A Retrospective Video-Review Study. Endoscopy International Open. 2026;14(CP). doi:10.1055/a-2976-6823
BibTeX
@article{Yang2026,
author = {Yang, Mei and Wang, Yujie and Shi, Li-Wei and Tang, Zhaorong and Xue, Mei and Luo, Ting and Shan, Jing and Jiang, Lin and Chen, Tianxu and Li, Junlin and Chen, Yuanyuan and Sun, Xiaobin},
title = {Narrow-Band Imaging with Acetic Acid Enhancement for Real-Time Optical Diagnosis of Colonic Polyps: A Retrospective Video-Review Study},
journal = {Endoscopy International Open},
year = {2026},
volume = {14},
number = {CP},
doi = {10.1055/a-2976-6823}
}
EUVIMED