Fachartikel in der Zeitschrift Klinische Monatsblätter für Augenheilkunde, erschienen am 26.10.2026. Verfasst von Fátima Cuellar und 3 weiteren Autor:innen. Beteiligte Einrichtung: Universitat Politècnica de Catalunya-BarcelonaTech, Applied Optics and Image Processing Group, Optics and Optometry Department, Barcelona, Spain, Ter…. Die Arbeit nennt 24 Literaturangaben. Gefördert von: Klaus Tschira Stiftung.
Abstract (Originalsprache)
Background
Enhanced monofocal intraocular lenses aim to improve intermediate vision while maintaining good distance visual acuity (VA), offering an alternative to multifocal IOLs. Mini-monovision can expand the range of vision without significantly compromising binocular quality. This study evaluated the visual performance of the RayOne EMV (RAO200E) and Acunex Quantum (AN6Q) IOLs under mini-monovision conditions using the SimVis Gekko simulator. Patients/Methods and Material Six healthy volunteers underwent a simulation with the SimVis Gekko. Ocular dominance was determined using the “hole-in-the-hand” test. Mini-monovision was induced by applying −0.5 and −1.0 D of myopia to the nondominant eye. Monocular and binocular defocus curves were measured from +0.5 to −2.5 D in 0.5 D increments under photopic conditions and cycloplegia. VA was assessed using standard logMAR charts at 4 m.
Results
Both IOLs provided excellent distance VA under emmetropic conditions. The Acunex Quantum IOL performed slightly better at intermediate distances. With −0.5 D of mini-monovision, the useful visual range (VA equal or better than 0.2 logMAR) reached −1.75 D for both IOL groups. When −1.0 D was induced, the useful visual range extended to −2.25 D, with binocular acuity at far distances. Both lenses benefited from mini-monovision without significantly compromising distance visual quality.
Conclusion
Simulated mini-monovision with enhanced monofocal IOLs effectively expands the functional range of vision, improving intermediate and near acuity while maintaining good distance vision. A −1.0 D compensation in the nondominant eye can provide good visual quality at all distances to improve spectacle independence in pseudophakic patients, with a small but noticeable difference between the two eyes.
Autor:innen und Institutionen
- Universitat Politècnica de Catalunya-BarcelonaTech, Applied Optics and Image Processing Group, Optics and Optometry Department, Barcelona, Spain, Terrassa.
- Heidelberg University, Departments of Ophthalmology, Germany, Heidelberg.
ORCID-Profile: Gerd U Auffarth, Grzegorz Łabuz
Förderung
- Klaus Tschira Stiftung
Zitieren
APA
Cuellar, F., Auffarth, G. U., Millán, M. S., & Łabuz, G. (2026). Adaptive Optics Simulation of Mini-monovision with Enhanced-monofocal Intraocular Lens Technology. Klinische Monatsblätter für Augenheilkunde. https://doi.org/10.1055/a-2967-8622
Vancouver
Cuellar F, Auffarth GU, Millán MS, Łabuz G. Adaptive Optics Simulation of Mini-monovision with Enhanced-monofocal Intraocular Lens Technology. Klinische Monatsblätter für Augenheilkunde. 2026. doi:10.1055/a-2967-8622
BibTeX
@article{Cuellar2026,
author = {Cuellar, Fátima and Auffarth, Gerd U and Millán, María S and Łabuz, Grzegorz},
title = {Adaptive Optics Simulation of Mini-monovision with Enhanced-monofocal Intraocular Lens Technology},
journal = {Klinische Monatsblätter für Augenheilkunde},
year = {2026},
doi = {10.1055/a-2967-8622}
}
EUVIMED