EUVIMEDEUVIMED entdecken
Klinische Studie

Marinelli Equation vs. DIN 6861-1: Comparison of the Achieved Therapeutic Thyroid Dose after Radioiodine Therapy Using Different Pretherapeutic Dosimetry

Patrick Heilfort iD, Olga Varlamova iD, Max Kranick, Jan Bredow, Michael Starke

Nuklearmedizin - NuclearMedicine · 05.10.2026

DOI: 10.1055/a-2960-8295 ↗

Kurz gefasst

Klinische Studie in der Zeitschrift Nuklearmedizin - NuclearMedicine, erschienen am 05.10.2026. Verfasst von Patrick Heilfort und 4 weiteren Autor:innen. Beteiligte Einrichtung: Medical University of Lausitz - Carl Thiem, Clinic for Nuclear Medicine, BB, Germany, Cottbus. Die Arbeit nennt 11 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Pretherapeutic dosimetry is an essential component of individualized radioiodine therapy. This study aimed to compare radioiodine therapies planned according to the Marinelli equation or DIN 6861-1:2021-11 with regard to the deviation of the planned and achieved thyroid doses in patients with benign thyroid diseases. The relative deviation of the achieved thyroid dose during radioiodine therapy from the pretherapeutically planned dose was analyzed according to the applied dosimetric method. Patient cohorts with goiter, recurrent goiter, disseminated and focal thyroid autonomy and autoimmune thyroid disease were evaluated. The cohorts were compared using the Mann–Whitney U- test. For goiter, recurrent goiter, disseminated thyroid autonomy and focal thyroid autonomy, radioiodine therapies planned according to DIN 6861-1:2021-11 were associated with significantly smaller deviations between the planned and achieved thyroid doses than therapies planned according to the Marinelli equation. Depending on the diagnostic group, the mean relative deviation was approximately 15 to 32 percentage points lower in the DIN cohorts. The DIN cohorts also showed less variability in dose deviations. In patients with autoimmune thyroid disease, no statistically significant differences of the mean relative deviation were observed between the dosimetric methods. However, variability was also lower in the DIN cohorts. The use of DIN 6861-1:2021-11 is associated with improved prediction of the thyroid dose compared with the Marinelli equation and may contribute to more precise individualized planning of radioiodine therapy in patients with benign thyroid diseases.

Autor:innen und Institutionen

  • Medical University of Lausitz - Carl Thiem, Clinic for Nuclear Medicine, BB, Germany, Cottbus.

ORCID-Profile: Patrick Heilfort, Olga Varlamova

Zitieren

APA

Heilfort, P., Varlamova, O., Kranick, M., Bredow, J., & Starke, M. (2026). Marinelli Equation vs. DIN 6861-1: Comparison of the Achieved Therapeutic Thyroid Dose after Radioiodine Therapy Using Different Pretherapeutic Dosimetry. Nuklearmedizin - NuclearMedicine. https://doi.org/10.1055/a-2960-8295

Vancouver

Heilfort P, Varlamova O, Kranick M, Bredow J, Starke M. Marinelli Equation vs. DIN 6861-1: Comparison of the Achieved Therapeutic Thyroid Dose after Radioiodine Therapy Using Different Pretherapeutic Dosimetry. Nuklearmedizin - NuclearMedicine. 2026. doi:10.1055/a-2960-8295

BibTeX
@article{Heilfort2026,
  author = {Heilfort, Patrick and Varlamova, Olga and Kranick, Max and Bredow, Jan and Starke, Michael},
  title = {Marinelli Equation vs. DIN 6861-1: Comparison of the Achieved Therapeutic Thyroid Dose after Radioiodine Therapy Using Different Pretherapeutic Dosimetry},
  journal = {Nuklearmedizin - NuclearMedicine},
  year = {2026},
  doi = {10.1055/a-2960-8295}
}
Kostenlos starten →