EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Modified Open-Loop Suture: A Reliable Alternative in Microvascular Anastomosis

Raquel Villar-Puchades, Ana Diaz-Cuevas, Francisco E. Olucha-Bordonau

Journal of Reconstructive Microsurgery Open · 01.07.2026 · 11 (02) · e67-e71

DOI: 10.1055/a-2944-0433 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Reconstructive Microsurgery Open, erschienen am 01.07.2026. Verfasst von Raquel Villar-Puchades und 2 weiteren Autor:innen. Die Arbeit nennt 10 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Microvascular patency is essential in free flap tissue transfer, and achieving an anastomosis in a shorter operative time helps reduce ischemia and ensures adequate tissue perfusion. Although various techniques have been proposed in microsurgery, the simple interrupted suture remains the gold standard for very small vessels. Continuous suturing can reduce anastomosis time; however, in small-caliber vessels, it carries the risk of incorporating the posterior wall and producing a purse-string effect, potentially compromising patency. The open-loop anastomosis technique described by Lee and colleagues represents a valuable alternative between interrupted and continuous suturing techniques. In this study, we modified the open-loop approach by employing a continuous suture arranged in a spiral configuration, in which the loops are sequentially interrupted and divided after each stitch is tied.

Methods

This technique was evaluated in the carotid arteries of 30 Sprague–Dawley rats. The simple interrupted suture was performed on one side and the modified open-loop suture on the contralateral side.

Results

The mean anastomosis time was 29.97 ± 7.78 min for the simple interrupted suture technique and 26.27 ± 5.61 min for the modified open-loop suture, with a statistically significant difference (p = 0.039). This technique resulted in a shorter operative time without compromising vascular patency.

Conclusion

The modified open-loop suture represents a viable and effective alternative to conventional microsurgical anastomosis techniques. It achieves patent anastomoses while reducing operative time.

Zitieren

APA

Villar-Puchades, R., Diaz-Cuevas, A., & Olucha-Bordonau, F. E. (2026). Modified Open-Loop Suture: A Reliable Alternative in Microvascular Anastomosis. Journal of Reconstructive Microsurgery Open, 11(02), e67-e71. https://doi.org/10.1055/a-2944-0433

Vancouver

Villar-Puchades R, Diaz-Cuevas A, Olucha-Bordonau FE. Modified Open-Loop Suture: A Reliable Alternative in Microvascular Anastomosis. Journal of Reconstructive Microsurgery Open. 2026;11(02):e67-e71. doi:10.1055/a-2944-0433

BibTeX
@article{VillarPuchades2026,
  author = {Villar-Puchades, Raquel and Diaz-Cuevas, Ana and Olucha-Bordonau, Francisco E.},
  title = {Modified Open-Loop Suture: A Reliable Alternative in Microvascular Anastomosis},
  journal = {Journal of Reconstructive Microsurgery Open},
  year = {2026},
  volume = {11},
  number = {02},
  pages = {e67--e71},
  doi = {10.1055/a-2944-0433}
}
Kostenlos starten →