The Effect of BMI on the Image Quality of CTA Scans for DIEP Flap Breast Reconstruction
Journal of Reconstructive Microsurgery · 25.09.2026
DOI: 10.1055/a-2943-3564 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Reconstructive Microsurgery, erschienen am 25.09.2026. Verfasst von Noah C O Terng und 4 weiteren Autor:innen. Beteiligte Einrichtung: Erasmus MC, University Medical Center Rotterdam, Department of Plastic and Reconstructive Surgery, Zuid-Holland, The Netherlands, Rotterdam. Die Arbeit nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Computed tomography angiography (CTA) imaging is currently the gold standard for the preoperative planning of deep inferior epigastric perforator (DIEP) flap breast reconstruction. Limited research has been performed on the effect of body mass index (BMI) on CTA image quality. Hence, we evaluated the association between BMI and CTA image quality. To investigate the association between BMI and image quality, the image quality of 100 CTA scans was scored on a 5-point Likert scale for five different perforator aspects: caliber, location of fascia penetration, intramuscular course, intramuscular branching, and subcutaneous branching. Ordinal regression was performed to determine the effect of BMI on the image quality of the scans. Image quality was scored highest for the subcutaneous branching with a mean score of 3.99 (standard deviation [SD]: 0.64), while the intramuscular branching showed the lowest scores with a mean of 3.35 (SD: 0.82). A higher BMI was associated with a statistically significant lower image quality regarding the assessment of the intramuscular course and intramuscular branching of the perforator, with a regression coefficient of − 0.648 and − 0.801, respectively. A higher BMI was associated with lower image quality with respect to the assessment of the intramuscular course and intramuscular branching in CTA scans for the preoperative planning of DIEP flap breast reconstruction.
Autor:innen und Institutionen
- Erasmus MC, University Medical Center Rotterdam, Department of Plastic and Reconstructive Surgery, Zuid-Holland, The Netherlands, Rotterdam.
- Erasmus MC, University Medical Center Rotterdam, Department of Radiology and Nuclear Medicine, Zuid-Holland, The Netherlands, Rotterdam.
ORCID-Profile: Marc A M Mureau
Zitieren
APA
Terng, N. C. O., Kos, T. M., Mureau, M. A. M., Bos, D., & Corten, E. M. L. (2026). The Effect of BMI on the Image Quality of CTA Scans for DIEP Flap Breast Reconstruction. Journal of Reconstructive Microsurgery. https://doi.org/10.1055/a-2943-3564
Vancouver
Terng NCO, Kos TM, Mureau MAM, Bos D, Corten EML. The Effect of BMI on the Image Quality of CTA Scans for DIEP Flap Breast Reconstruction. Journal of Reconstructive Microsurgery. 2026. doi:10.1055/a-2943-3564
BibTeX
@article{Terng2026,
author = {Terng, Noah C O and Kos, Tessa M and Mureau, Marc A M and Bos, Daniel and Corten, Eveline M L},
title = {The Effect of BMI on the Image Quality of CTA Scans for DIEP Flap Breast Reconstruction},
journal = {Journal of Reconstructive Microsurgery},
year = {2026},
doi = {10.1055/a-2943-3564}
}
EUVIMED