A Multicenter Prospective Feasibility Study of a Novel Rapid-Exchange Biliary Stent Delivery System Enabling Sequential Stent Placement with Index Guidewire Retention
Endoscopy International Open · 21.10.2026 · 14 (CP)
DOI: 10.1055/a-2942-4784 ↗Kurz gefasst
Fachartikel in der Zeitschrift Endoscopy International Open, erschienen am 21.10.2026. Verfasst von Jennifer Ma und 10 weiteren Autor:innen. Beteiligte Einrichtung: Center for Interventional Gastroenterology at UTHealth HoustonThe University of Texas Health Science Center at HoustonHoustonTexasUnited States. Die Arbeit nennt 14 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Background and Aims Biliary stenting is essential for the management of biliary obstruction. All plastic biliary stent delivery systems in the United States require withdrawal of the guidewire upon stent deployment, mandating repeat cannulation when additional stents are required. A novel multiple biliary stent delivery system with a self-detaching tip preserves the index guidewire in situ after stent release, enabling rapid sequential placement of additional plastic stents. We report the first-in-human multicenter clinical experience with this device.
Methods
This was a prospective feasibility pilot study at 7 international tertiary referral centers. Endoscopists were trained using a 2-minute video and bedside proctoring. Adult patients undergoing endoscopic retrograde cholangiopancreatography (ERCP) with the novel system between 2023 and 2024 were enrolled. Primary endpoints were technical success of stent deployment and index guidewire retention. Secondary endpoints included stents placed per session, ability to advance the system to the intended location, immediate adverse events (AE), and endoscopist-reported usability.
Results
Twenty-five patients underwent ERCP with the novel system. Between 1 and 4 plastic stents were placed in parallel per session. Technical success was achieved in 24 of 25 cases (96.0%); one stent could not be delivered owing to severe ampullary angulation. The index guidewire was retained in situ in 100% of successfully delivered stents.
Conclusion
In this first-in-human multicenter experience, a novel rapid-exchange biliary stent delivery system with a self-detaching tip enabled sequential parallel plastic stent placement without removal of the index guidewire, with high technical success and no immediate procedure-related adverse events. Further prospective comparative study is warranted.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Center for Interventional Gastroenterology at UTHealth HoustonThe University of Texas Health Science Center at HoustonHoustonTexasUnited States.
- Division of Gastroenterology and HepatologyJohns Hopkins MedicineBaltimoreMarylandUnited States.
- Division of GastroenterologyHCA Florida Largo HospitalLargoFloridaUnited States.
- GastroenterologyZiv Medical CenterSafedIsrael.
- Texas Digestive Disease Consultants PLLCSouthlakeTexasUnited States.
- GastroenterologyMontefiore Health System, Albert Einstein College of MedicineNew YorkNew YorkUnited States.
ORCID-Profile: Jennifer Ma
Zitieren
APA
Ma, J., Desai, M., Singh, V. K., Mizrahi, M., Bezobchuk, S., Nguyen, D., Joseph-Talreja, M., Raijman, I., Ho, S., Khashab, M. A., & Thosani, N. (2026). A Multicenter Prospective Feasibility Study of a Novel Rapid-Exchange Biliary Stent Delivery System Enabling Sequential Stent Placement with Index Guidewire Retention. Endoscopy International Open, 14(CP). https://doi.org/10.1055/a-2942-4784
Vancouver
Ma J, Desai M, Singh VK, Mizrahi M, Bezobchuk S, Nguyen D, et al. A Multicenter Prospective Feasibility Study of a Novel Rapid-Exchange Biliary Stent Delivery System Enabling Sequential Stent Placement with Index Guidewire Retention. Endoscopy International Open. 2026;14(CP). doi:10.1055/a-2942-4784
BibTeX
@article{Ma2026,
author = {Ma, Jennifer and Desai, Madhav and Singh, Vikesh K and Mizrahi, Meir and Bezobchuk, Stanislav and Nguyen, Dang and Joseph-Talreja, Mairin and Raijman, Isaac and Ho, Sammy and Khashab, Mouen A and Thosani, Nirav},
title = {A Multicenter Prospective Feasibility Study of a Novel Rapid-Exchange Biliary Stent Delivery System Enabling Sequential Stent Placement with Index Guidewire Retention},
journal = {Endoscopy International Open},
year = {2026},
volume = {14},
number = {CP},
doi = {10.1055/a-2942-4784}
}
EUVIMED