Technical Assessment of Simulated Neonatal Intubation Using Multi-Angle Video
American Journal of Perinatology · 27.08.2026
DOI: 10.1055/a-2938-9439 ↗Kurz gefasst
Fachartikel in der Zeitschrift American Journal of Perinatology, online erschienen am 27.08.2026. Verfasst von Hannah Gu und 10 weiteren Autor:innen. Beteiligte Einrichtung: Stanford University School of Medicine, Department of Pediatrics/Neonatology, California, United States, Palo Alto. Die Arbeit nennt 34 Literaturangaben. Gefördert von: The Neonatal Resuscitation Program of the American Academy of Pediatrics.
Abstract (Originalsprache)
Neonatal intubation is a critical skill, yet trainees may not achieve procedural competency before program completion. This study quantified technical differences between novice and expert intubators using multi-angle and intraoral video during simulated neonatal intubation. Participants from a level IV NICU—including MDs, neonatal nurse practitioners, registered nurse transport specialists, and residents—completed three intubations each on preterm and term manikins. Experts were defined as those with > 10 successful intubations and > 1 year of NICU experience. Outcomes included failure rate, time metrics, glottic view, and laryngoscope hold. Thirty-eight subjects participated (18 novices and 20 experts). Intubation failure did not differ significantly, but experts completed term manikin intubations faster (12.5 seconds vs. 15.8 seconds, p < 0.001), visualized cords sooner in preterm trials, and advanced the endotracheal tube faster in term trials. Glottic views were similar, though laryngoscope hold technique differed significantly (p = 0.006). Objective technique differences may inform targeted training strategies and competency assessment in neonatal airway management.
Autor:innen und Institutionen
- Stanford University School of Medicine, Department of Pediatrics/Neonatology, California, United States, Palo Alto.
- University of California, San Francisco, California, United States, San Francisco.
- Georgetown University, District of Columbia, United States, Washington.
- University of New Hampshire, Department of Nursing, New Hampshire, United States, Durham.
- Franklin Pierce University, Department of Nursing, New Hampshire, United States, Rindge.
ORCID-Profile: Hannah Gu, Rodrigo B Galindo
Förderung
- The Neonatal Resuscitation Program of the American Academy of Pediatrics
Zitieren
APA
Gu, H., Galindo, R. B., Cranshaw, M., Alade, T., Fuerch, J. H., Yamada, N. K., Hunt, K., Pineda, L., McWilliam, P., Kent, N., & Halamek, L. P. (2026). Technical Assessment of Simulated Neonatal Intubation Using Multi-Angle Video. American Journal of Perinatology. https://doi.org/10.1055/a-2938-9439
Vancouver
Gu H, Galindo RB, Cranshaw M, Alade T, Fuerch JH, Yamada NK, et al. Technical Assessment of Simulated Neonatal Intubation Using Multi-Angle Video. American Journal of Perinatology. 2026. doi:10.1055/a-2938-9439
BibTeX
@article{Gu2026,
author = {Gu, Hannah and Galindo, Rodrigo B and Cranshaw, Matthew and Alade, Tami and Fuerch, Janene H and Yamada, Nicole K and Hunt, Katie and Pineda, Lisa and McWilliam, Paula and Kent, Nancy and Halamek, Louis P},
title = {Technical Assessment of Simulated Neonatal Intubation Using Multi-Angle Video},
journal = {American Journal of Perinatology},
year = {2026},
doi = {10.1055/a-2938-9439}
}