EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Rapid Quantitative Analysis of Amino Acids in Compound Amino Acid Injection Using Presaturation Water Suppression NMR Spectroscopy

Wenyu Xu, Yayi Hu, Ben Zhou, Shiqiao Li, Youzhi Jia, Hongjuan Pan

Pharmaceutical Fronts · 01.09.2026 · 08 (03) · e298-e305

DOI: 10.1055/a-2928-1116 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Pharmaceutical Fronts, erschienen am 01.09.2026. Verfasst von Wenyu Xu und 5 weiteren Autor:innen. Die Arbeit nennt 14 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Compound amino acid injection (CAAI) is an injectable preparation containing multiple amino acids, clinically indicated for patients with impaired protein intake, absorption disorders, or unmet nutritional needs. Conventional chromatography-based methods for detecting the amino acids require derivatization and are time-consuming. In this study, a quantitative nuclear magnetic resonance (qNMR) technology combined with water suppression by presaturation was developed for rapid quantification of nine amino acids in CAAI-9AA, in which 9AA serves as a specification code denoting a formulation comprising nine amino acids. Maleic acid (MA) and 3-(trimethylsilyl)propionic acid-d4 sodium salt (TMSP) were employed as dual internal standards, and deuterated pyridine as a chemical shift reagent and pH adjuster. Method validation demonstrated excellent agreement with reference liquid chromatography results (deviation within ± 3%). The assay showed good linearity (R 2 ≥ 0.999) within a certain concentration range and exhibited excellent precision and repeatability with a relative standard deviation (RSD) below 2.0%. The recovery values were between 96.75 and 108.10%. This validated qNMR method enables rapid and accurate quantification of amino acid components, confirming its practicality for routine pharmaceutical analysis and providing a novel, feasible strategy for the quantitation of more component amino acid formulations.

Zitieren

APA

Xu, W., Hu, Y., Zhou, B., Li, S., Jia, Y., & Pan, H. (2026). Rapid Quantitative Analysis of Amino Acids in Compound Amino Acid Injection Using Presaturation Water Suppression NMR Spectroscopy. Pharmaceutical Fronts, 08(03), e298-e305. https://doi.org/10.1055/a-2928-1116

Vancouver

Xu W, Hu Y, Zhou B, Li S, Jia Y, Pan H. Rapid Quantitative Analysis of Amino Acids in Compound Amino Acid Injection Using Presaturation Water Suppression NMR Spectroscopy. Pharmaceutical Fronts. 2026;08(03):e298-e305. doi:10.1055/a-2928-1116

BibTeX
@article{Xu2026,
  author = {Xu, Wenyu and Hu, Yayi and Zhou, Ben and Li, Shiqiao and Jia, Youzhi and Pan, Hongjuan},
  title = {Rapid Quantitative Analysis of Amino Acids in Compound Amino Acid Injection Using Presaturation Water Suppression NMR Spectroscopy},
  journal = {Pharmaceutical Fronts},
  year = {2026},
  volume = {08},
  number = {03},
  pages = {e298--e305},
  doi = {10.1055/a-2928-1116}
}
Kostenlos starten →