Potential of Artificial Intelligence to Estimate the Birthweight of Newborns Based on Ultrasound Data – Comparison between AI and Hadlock Formula
Potenzial künstlicher Intelligenz zur Schätzung des Geburtsgewichts Neugeborener anhand von Ultraschalldaten – Vergleich zwischen KI und Hadlock-Formel
Geburtshilfe und Frauenheilkunde · 2026-11 · 86 (11) · 976-984
DOI: 10.1055/a-2915-6606 ↗Auf einen Blick
In 17.691 Ultraschalluntersuchungen war ein KI-Modell zur Geburtsgewichtsprognose genauer als die Hadlock-Formel. Auch für Makrosomie zeigten KI-Modelle gute AUC-Werte.
Fragestellung
Kann ein mit künstlicher Intelligenz entwickeltes Vorhersagemodell Geburtsgewicht oder Makrosomie genauer vorhersagen als die Hadlock-Formel?
Methode
17.691 Sonografien von 2013–2022; Datensatz in Training, Validierung und Test aufgeteilt; mehrere Machine-Learning-Methoden getestet.
Ergebnisse
Beste Regression mit Random Forest: RMSE 315,071 (SD 10,055) vs. Hadlock-Formel RMSE 323,14. AUC bei 4000 g: 0,889 (SD 0,008) mit Deep Neural Network. Bei 4500 g: Random Forest 0,894 (SD 0,054), Deep Neural Network 0,910 (SD 0,032).
Schlussfolgerung der Autor:innen
KI-gestützte Modelle wie Random Forest und Deep Neural Network ermöglichen laut Autor:innen eine genaue Vorhersage von Makrosomie und Geburtsgewicht.
Kernaussagen
- Random-Forest-Regression zeigte die beste Geburtsgewichtsprognose
- KI war besser als die Hadlock-Formel im RMSE
- Gute AUC-Werte für Makrosomie bei 4000 g und 4500 g
Deutsche Zusammenfassung: KI-gestützt aus dem Original-Abstract erstellt; alle Zahlen wurden automatisch mit dem Original abgeglichen. Maßgeblich ist der Original-Abstract.
Kurz gefasst
Fachartikel in der Zeitschrift Geburtshilfe und Frauenheilkunde, online erschienen am 24.08.2026. Verfasst von Natalia Anna Kaufmann und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Gynaecology, Obstetrics and Gyn. EndocrinologyJohannes Kepler University Linz, Kepler University HospitalLinzAustria. Die Arbeit nennt 16 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
When managing labor and delivery, an accurate estimation of fetal weight is essential. The aim of this study was to compare if a prediction model developed by Artificial intelligence (AI) can predict fetal birthweight or macrosomia with greater accuracy than the Hadlock formula, which is commonly used to estimate fetal weight at the time of ultrasound. 17691 ultrasonography exams from 2013–2022 were included in this study. The dataset was split. The first 70% of the data were used for training the models, the results were validated on 15% of the data and the remaining 15% were designated as the testing dataset. Several machine learning methods were examined. Three AI models were created: the regression model to predict the birthweight and two classification models to predict a birthweight of over 4000 g and over 4500 g respectively. In the regression model the best prediction accuracy was attained with random forest regression (RMSE 315.071, SD 10.055). These results were better compared to the Hadlock formula (RMSE of 323.14). In the classification model with a threshold of 4000 g the best result was achieved with deep neural network (AUC 0.889, SD 0.008). Similarly in the second classification model (threshold 4500 g) the best results were observed with random forest classification (AUC 0.894, SD 0.054) and with deep neural network (AUC 0.910, SD 0.032). AI-supported models such as random forest and deep neural network facilitate accurate prediction of macrosomia and fetal weight at birth by considering a variety of parameters.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Gynaecology, Obstetrics and Gyn. EndocrinologyJohannes Kepler University Linz, Kepler University HospitalLinzAustria.
- Department of Anaesthesiology and Intensive CareJohannes Kepler University Linz, Kepler University HospitalLinzAustria.
ORCID-Profile: Natalia Anna Kaufmann
Zitieren
APA
Kaufmann, N. A., Oppelt, P., Meier, J., Eichinger, T., Enengl, S., Lastinger, J., & Reiter, E. (2026). Potential of Artificial Intelligence to Estimate the Birthweight of Newborns Based on Ultrasound Data – Comparison between AI and Hadlock Formula. Geburtshilfe und Frauenheilkunde, 86(11), 976-984. https://doi.org/10.1055/a-2915-6606
Vancouver
Kaufmann NA, Oppelt P, Meier J, Eichinger T, Enengl S, Lastinger J, et al. Potential of Artificial Intelligence to Estimate the Birthweight of Newborns Based on Ultrasound Data – Comparison between AI and Hadlock Formula. Geburtshilfe und Frauenheilkunde. 2026;86(11):976-984. doi:10.1055/a-2915-6606
BibTeX
@article{Kaufmann2026,
author = {Kaufmann, Natalia Anna and Oppelt, Peter and Meier, Jens and Eichinger, Teresa and Enengl, Sabine and Lastinger, Julia and Reiter, Elisabeth},
title = {Potential of Artificial Intelligence to Estimate the Birthweight of Newborns Based on Ultrasound Data – Comparison between AI and Hadlock Formula},
journal = {Geburtshilfe und Frauenheilkunde},
year = {2026},
volume = {86},
number = {11},
pages = {976--984},
doi = {10.1055/a-2915-6606}
}