EUVIMEDEUVIMED entdecken
Multizentrische StudieOpen Access · CC BY-NC-ND 4.0

Evaluating the human–artificial intelligence interaction in optical diagnosis of early colorectal carcinoma through endoscopist responses to simulated artificial intelligence: a multinational online study

Bewertung der Mensch-KI-Interaktion bei der optischen Diagnose des frühen Kolorektalkarzinoms anhand von Endoskopist:innen-Antworten auf simulierte KI: multinationale Online-Studie

Ayla Thijssen iD, Ramon-Michel Schreuder, Nikoo Dehghani, Evelien Dekker iD, Jurjen J Boonstra, Ruud W M Schrauwen, Martine A M C Baven-Pronk, Jochim S Terhaar Sive Droste, Philip R Bos, Wouter H de Vos Tot Nederveen Cappel, Muhammed Hadithi, Jan-Willem A Straathof und 15 weitere

Endoscopy · 01.11.2026 · 58 (11) · 1303-1309

DOI: 10.1055/a-2912-9478 ↗

Auf einen Blick

Bei 78 Endoskopist:innen stieg die diagnostische Genauigkeit nach simulierter KI von 71,4 % auf 73,7 %. Ein unangemessenes Reagieren auf KI wurde bei 28,2 % beobachtet.

Fragestellung

Wie beeinflusst simulierte KI die optische Diagnose des Kolorektalkarzinoms durch Endoskopist:innen?

Methode

Internationale Online-Studie mit 78 Endoskopist:innen; 15 Videos vor und 35 Videos nach simulierter KI-Diagnose; Histologie als Goldstandard; Vergleich vor und nach KI mit Signalentdeckungstheorie.

Ergebnisse

In 2730 Diagnosen lag die Genauigkeit vor KI bei 71,4 % und nach KI bei 73,7 % (P < 0,001). Vor KI: mittlere Hit-Rate 0,86, mittlere False-Alarm-Rate 0,35. Unangemessene Reaktion auf KI bei 28,2 %.

Schlussfolgerung der Autor:innen

Unangemessene Reaktionen auf KI sind ein Problem in der Mensch-KI-Interaktion bei der optischen Diagnose des CRC.

Kernaussagen

  • Genauigkeit vor KI 71,4 %, nach KI 73,7 %
  • Unangemessene Reaktion auf KI bei 28,2 %
  • 41,0 % wechselten nach KI zu einer konservativeren Diagnose

Deutsche Zusammenfassung: KI-gestützt aus dem Original-Abstract erstellt; alle Zahlen wurden automatisch mit dem Original abgeglichen. Maßgeblich ist der Original-Abstract.

Kurz gefasst

Multizentrische Studie in der Zeitschrift Endoscopy, erschienen am 01.11.2026. Verfasst von Ayla Thijssen und 26 weiteren Autor:innen. Beteiligte Einrichtung: Department of Gastroenterology and Hepatology, Maastricht University Medical Center+, Maastricht, Netherlands. Hauptthemen laut MEDLINE: Colorectal Neoplasms, Artificial Intelligence, Colonoscopy, Early Detection of Cancer. Die Arbeit nennt 16 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Nederlandse Organisatie voor Wetenschappelijk Onderzoek.

Auf einen BlickAbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Suboptimal human–artificial intelligence (AI) interaction is a potential roadblock for implementation of AI in clinical practice. We aimed to evaluate the interaction between AI and endoscopists in the optical diagnosis of colorectal carcinoma (CRC).

Methods

International endoscopists were invited to diagnose colorectal lesions online. After a pretest of 15 videos, the diagnosis could be adjusted in the subsequent 35 videos after receiving a simulated AI diagnosis. Histology was the gold standard. Endoscopists’ diagnoses before and after AI were compared using the signal detection theory. Inappropriate response to AI was defined as decreased diagnostic performance by the endoscopist after AI.

Results

In 2730 diagnoses, the 78 participating endoscopists reached diagnostic accuracies of 71.4 % before and 73.7 % after AI (P < 0.001). Before AI, endoscopists missed only a few true CRCs (mean hit rate 0.86), at the cost of a mean false alarm rate of 0.35. Inappropriate response to AI was observed in 28.2 % of endoscopists. After AI, most endoscopists (41.0 %) shifted toward a more conservative attitude, tending to diagnose a lesion as non-CRC.

Conclusions

Inappropriate response to AI is an issue in human–AI interaction for the optical diagnosis of CRC. Before using AI, endoscopists should become familiar with their own optical diagnostic performance, and that of the AI system, to possibly improve interaction.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Colorectal NeoplasmsArtificial IntelligenceColonoscopyEarly Detection of CancerHumansClinical CompetenceAttitude of Health Personnel

Autor:innen und Institutionen

  • Department of Gastroenterology and Hepatology, Maastricht University Medical Center+, Maastricht, Netherlands.
  • GROW Research Institute for Oncology and Reproduction, Maastricht University, Maastricht, Netherlands.
  • Department of Gastroenterology and Hepatology, Catharina Hospital, Eindhoven, Netherlands.
  • Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, Netherlands.
  • Department of Gastroenterology and Hepatology, Amsterdam University Medical Centres, Amsterdam, Netherlands.
  • Department of Gastroenterology and Hepatology, Leiden University Medical Center, Leiden, Netherlands.

ORCID-Profile: Ayla Thijssen, Evelien Dekker, Leon M G Moons, Fons van der Sommen

Förderung

  • Nederlandse Organisatie voor Wetenschappelijk Onderzoek

Zitieren

APA

Thijssen, A., Schreuder, R. M., Dehghani, N., Dekker, E., Boonstra, J. J., Schrauwen, R. W. M., Baven-Pronk, M. A. M. C., Terhaar Sive Droste, J. S., Bos, P. R., de Vos Tot Nederveen Cappel, W. H., Hadithi, M., Straathof, J. A., Bulte, G. J., Bastiaansen, B. A. J., Hoge, C. V., Perk, L. E., Groen, J. N., Borg, F. T., van Leerdam, M. E., …, & Dutch T1 Colorectal Cancer Working Group and COMET T1 CRC study group (2026). Evaluating the human–artificial intelligence interaction in optical diagnosis of early colorectal carcinoma through endoscopist responses to simulated artificial intelligence: a multinational online study. Endoscopy, 58(11), 1303-1309. https://doi.org/10.1055/a-2912-9478

Vancouver

Thijssen A, Schreuder RM, Dehghani N, Dekker E, Boonstra JJ, Schrauwen RWM, et al. Evaluating the human–artificial intelligence interaction in optical diagnosis of early colorectal carcinoma through endoscopist responses to simulated artificial intelligence: a multinational online study. Endoscopy. 2026;58(11):1303-1309. doi:10.1055/a-2912-9478

BibTeX
@article{Thijssen2026,
  author = {Thijssen, Ayla and Schreuder, Ramon-Michel and Dehghani, Nikoo and Dekker, Evelien and Boonstra, Jurjen J and Schrauwen, Ruud W M and Baven-Pronk, Martine A M C and Terhaar Sive Droste, Jochim S and Bos, Philip R and de Vos Tot Nederveen Cappel, Wouter H and Hadithi, Muhammed and Straathof, Jan-Willem A and Bulte, Geert J and Bastiaansen, Barbara A J and Hoge, Chantal V and Perk, Lars E and Groen, John N and Borg, Frank Ter and van Leerdam, Monique E and Rondagh, Eveline J A and de With, Peter H N and Smulders, Fren T Y and Winkens, Bjorn and Moons, Leon M G and van der Sommen, Fons and Schoon, Erik J and Dutch T1 Colorectal Cancer Working Group and COMET T1 CRC study group, Dutch T1 Colorectal Cancer Working Group and COMET T1 CRC study group},
  title = {Evaluating the human–artificial intelligence interaction in optical diagnosis of early colorectal carcinoma through endoscopist responses to simulated artificial intelligence: a multinational online study},
  journal = {Endoscopy},
  year = {2026},
  volume = {58},
  number = {11},
  pages = {1303--1309},
  doi = {10.1055/a-2912-9478}
}
Kostenlos starten →