EUVIMEDEUVIMED entdecken
Randomisierte kontrollierte StudieOpen Access

Spatially Integrated Electronic Health Record Prototype Improves Usability and Reduces Cognitive Load for Intensive Care Nurses: A Randomized Crossover Trial

Spatially Integrated Electronic Health Record Prototype verbessert die Usability und senkt die kognitive Belastung bei Intensivpflegekräften: randomisierte Crossover-Studie

Lee Taylor-Vaughan iD, Morrison W Helena, Graciela E Silva Torres, Kimberly D Shea, Pamela G Reed, Sheila M Gephart

Applied Clinical Informatics · 01.05.2026 · 17 (03) · 604-614

DOI: 10.1055/a-2903-5822 ↗

Auf einen Blick

Bei 36 Intensivpflegekräften führte ein Spatial Awareness Integrated Electronic Health Record (SAI-EHR) zu schnellerer Dokumentation und geringerer kognitiver Belastung als ein lineares Flowsheet-Interface.

Fragestellung

Welche Auswirkungen hat ein Spatial Awareness Integrated Electronic Health Record (SAI-EHR) im Vergleich zu einem traditionellen linearen Flowsheet-Interface auf Effizienz, Usability und kognitive Belastung bei Intensivpflegekräften?

Methode

Randomisierte, zwei-periodige Crossover-Simulation mit 36 Intensivpflegekräften; Vergleich von SAI-EHR mit LID-EHR. Primäre Endpunkte: Dokumentationseffizienz, SUS und NASA-TLX; Analyse mit linearen Mixed-Effects-Modellen.

Ergebnisse

SAI-EHR verkürzte die Dokumentationszeit um 177 Sekunden (27 %; p < 0,001; d = 0,88) und senkte den NASA-TLX um 51,3 % (18,44 vs. 37,82; p < 0,001; d = 0,73). Die Genauigkeit war höher (98,70 % vs. 92,86 %; p < 0,001; d = 0,68).

Einschränkungen

SUS und wahrgenommener Nutzen unterschieden sich nicht signifikant; die Autor:innen nennen für diese Vergleiche eine größere Stichprobe als nötig.

Schlussfolgerung der Autor:innen

Ein SAI-EHR-Prototyp ermöglichte schnellere und genauere Dokumentation bei geringerer wahrgenommener Belastung als ein lineares Flowsheet-Interface. Die Inanspruchnahme fiel höher aus; formale Usability- und Nutzenvergleiche brauchen größere Studien.

Kernaussagen

  • 177 Sekunden kürzere Dokumentationszeit pro Aufgabe
  • NASA-TLX mit SAI-EHR niedriger (18,44 vs. 37,82)
  • Genauigkeit höher; TAM-BI mit SAI-EHR höher

Deutsche Zusammenfassung: KI-gestützt aus dem Original-Abstract erstellt; alle Zahlen wurden automatisch mit dem Original abgeglichen. Maßgeblich ist der Original-Abstract.

Kurz gefasst

Randomisierte kontrollierte Studie in der Zeitschrift Applied Clinical Informatics, erschienen am 01.05.2026. Verfasst von Lee Taylor-Vaughan und 5 weiteren Autor:innen. Beteiligte Einrichtung: The University of Arizona, College of Nursing, United States, Arizona. Hauptthemen laut MEDLINE: Electronic Health Records, Cognition, Workload, Nurses. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

Auf einen BlickAbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study evaluated the effect of a Spatial Awareness Integrated Electronic Health Record (SAI-EHR) prototype on efficiency, usability, and cognitive workload among intensive care nurses performing standardized documentation tasks, compared with a traditional linear flowsheet-style interface (LID-EHR). A randomized, two-period crossover simulation was conducted with 36 intensive care unit (ICU) nurses who completed two standardized scenarios. Primary outcomes were documentation efficiency (time to complete a fixed task), usability (System Usability Scale [SUS]), and cognitive workload (NASA Task Load Index [NASA-TLX]). Secondary outcomes included accuracy and Technology Acceptance Model (TAM) measures of Perceived Usefulness (TAM-PU) and Behavioral Intention (TAM-BI). Analyses used linear mixed-effects models. Within-participant effect sizes were calculated using Cohen's d. SAI-EHR reduced documentation time by 177 seconds (27% faster; p < 0.001, d = 0.88) per task. NASA-TLX workload scores were 51.3% lower with SAI-EHR compared with the LID-EHR (18.44 vs. 37.82; p < 0.001, d = 0.73). Accuracy was 6.3% higher with SAI-EHR (98.70 vs. 92.86%; p < 0.001, d = 0.68). SUS and perceived usefulness scores favored SAI-EHR but did not differ significantly (SUS: 77.99 vs. 71.60; TAM-PU: 3.72 vs. 3.38). TAM-BI was substantially higher for SAI-EHR (25.5% increase; Δ = 0.96; 95% confidence interval [CI]: 0.55–1.36; p < 0.001, d = 0.72). Lower cognitive workload was associated with a stronger intention to adopt (r = −0.64; p < 0.001). An SAI-EHR prototype mirroring ICU room layout enabled faster, more accurate documentation with lower perceived workload than a linear flowsheet interface. Stated intention to adopt was higher and inversely associated with workload; differences in SUS and TAM perceived usefulness scores favored the spatial interface but did not reach statistical significance in this sample. Findings support spatial awareness integration as a workload-reducing design principle, while formal usability and usefulness comparisons warrant a larger-sample evaluation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Electronic Health RecordsCognitionWorkloadNursesIntensive Care UnitsCritical CareHumansCross-Over StudiesUser-Computer Interface

Autor:innen und Institutionen

  • The University of Arizona, College of Nursing, United States, Arizona.
  • College of Nursing, The University of Arizona, United States, Arizona.

ORCID-Profile: Lee Taylor-Vaughan

Zitieren

APA

Taylor-Vaughan, L., Helena, M. W., Silva Torres, G. E., Shea, K. D., Reed, P. G., & Gephart, S. M. (2026). Spatially Integrated Electronic Health Record Prototype Improves Usability and Reduces Cognitive Load for Intensive Care Nurses: A Randomized Crossover Trial. Applied Clinical Informatics, 17(03), 604-614. https://doi.org/10.1055/a-2903-5822

Vancouver

Taylor-Vaughan L, Helena MW, Silva Torres GE, Shea KD, Reed PG, Gephart SM. Spatially Integrated Electronic Health Record Prototype Improves Usability and Reduces Cognitive Load for Intensive Care Nurses: A Randomized Crossover Trial. Applied Clinical Informatics. 2026;17(03):604-614. doi:10.1055/a-2903-5822

BibTeX
@article{TaylorVaughan2026,
  author = {Taylor-Vaughan, Lee and Helena, Morrison W and Silva Torres, Graciela E and Shea, Kimberly D and Reed, Pamela G and Gephart, Sheila M},
  title = {Spatially Integrated Electronic Health Record Prototype Improves Usability and Reduces Cognitive Load for Intensive Care Nurses: A Randomized Crossover Trial},
  journal = {Applied Clinical Informatics},
  year = {2026},
  volume = {17},
  number = {03},
  pages = {604--614},
  doi = {10.1055/a-2903-5822}
}
Kostenlos starten →