A Balloon-assisted Colonoscope does not Increase the Adenoma Miss Rate: Outcomes of a Single-center Tandem Randomized Clinical Trial
Endoscopy International Open · 24.07.2026 · 14 (CP)
DOI: 10.1055/a-2901-5859 ↗Kurz gefasst
Randomisierte kontrollierte Studie in der Zeitschrift Endoscopy International Open, erschienen am 24.07.2026. Verfasst von Jean-Philippe Ratone und 7 weiteren Autor:innen. Beteiligte Einrichtung: Endoscopy UnitPaoli-Calmettes InstituteMarseilleProvence-Alpes-Côte d'AzurFrance. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Background
Colorectal cancer is the third leading cause of cancer death worldwide. Colonoscopy can prevent this complication but is imperfect because of missed adenoma. A device involving a variable-rigidity balloon has been developed: G-EYE colonoscopy (GEYEC). Only a few prospective studies on GEYEC are available. We compared GEYEC to standard colonoscopy (SC) during screening colonoscopy.
Methods
We performed a single-center back-to-back colonoscopy tandem randomized clinical trial. Patients older than 50 years were referred for screening colonoscopy, among whom one-third with a positive fecal immunochemical test were included. In Arm A, patients underwent SC followed by GEYEC; in Arm B, the opposite occurred. The primary objective was to assess and compare adenoma miss rate (AMR) between arms. The secondary objectives were to compare advanced AMRs (aAMRs), adverse events for each colonoscope and withdrawal stability rates for GEYEC.
Results
One hundred ninety-five patients were included between January 2020 and June 2023. A total of 164 patients (83 women, 51%) completed the two procedures, performed by six experienced operators. The mean AMRs were 0.438 in Arm A and 0.393 in Arm B (p = 0.713). The mean aAMRs were 0.176 in Arm A and 0.036 in Arm B (p = 0.76). The rate of significant adverse events (≥AGREE II) was 1.8%, and none were attributed to the GEYEC balloon. In 79% of cases, operators felt that GEYEC provided more stability during withdrawal.
Conclusion
Although it is reliable and safe, compared with SC, GEYEC does not reduce AMR or aAMR. However, it increases the comfort of scope withdrawal during screening.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Endoscopy UnitPaoli-Calmettes InstituteMarseilleProvence-Alpes-Côte d'AzurFrance.
- Clinical & Innovation Research Direction, Biostastistics & Methodology UnitPaoli-Calmettes InstituteMarseilleProvence-Alpes-Côte d'AzurFrance.
- Pathology UnitPaoli-Calmettes InstituteMarseilleProvence-Alpes-Côte d'AzurFrance.
ORCID-Profile: Jean-Philippe Ratone
Zitieren
APA
Ratone, J. P., Dahel, Y., Zemmour, C., Hoibian, S., Pesenti, C., Poizat, F., Giovannini, M., & Caillol, F. (2026). A Balloon-assisted Colonoscope does not Increase the Adenoma Miss Rate: Outcomes of a Single-center Tandem Randomized Clinical Trial. Endoscopy International Open, 14(CP). https://doi.org/10.1055/a-2901-5859
Vancouver
Ratone JP, Dahel Y, Zemmour C, Hoibian S, Pesenti C, Poizat F, et al. A Balloon-assisted Colonoscope does not Increase the Adenoma Miss Rate: Outcomes of a Single-center Tandem Randomized Clinical Trial. Endoscopy International Open. 2026;14(CP). doi:10.1055/a-2901-5859
BibTeX
@article{Ratone2026,
author = {Ratone, Jean-Philippe and Dahel, Yanis and Zemmour, Cristophe and Hoibian, Solène and Pesenti, Christian and Poizat, Florat and Giovannini, Marc and Caillol, Fabrice},
title = {A Balloon-assisted Colonoscope does not Increase the Adenoma Miss Rate: Outcomes of a Single-center Tandem Randomized Clinical Trial},
journal = {Endoscopy International Open},
year = {2026},
volume = {14},
number = {CP},
doi = {10.1055/a-2901-5859}
}
EUVIMED