EUVIMEDEUVIMED entdecken
Crossref

Computed Tomographic Measurement of Cementless Total Hip Replacement Implant Orientation

Jonathan Pink, Alexis Bilmont

Veterinary and Comparative Orthopaedics and Traumatology · 18.08.2026

DOI: 10.1055/a-2889-7878 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Veterinary and Comparative Orthopaedics and Traumatology, erschienen am 18.08.2026. Verfasst von Jonathan Pink und 1 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

The aim of this study was to describe and assess a technique for the measurement of cementless (BioMedtrix Biologic Fixation [BFX]) total hip replacement implant orientation using computed tomography (CT). Study Design Postoperative CT studies of 15 dogs that had total hip replacement with a 24 mm BFX cup and BFX stem were reviewed retrospectively. Multiplanar reconstructed CT images were manipulated to generate standard positions of the pelvis and femur. Open face version, angle of lateral opening (ALO), inclination of the cup and stem anteversion were measured sequentially. Cases were anonymized, randomized and measured three times by two observers.

Results

Intraclass correlation coefficients for cup open face version, cup ALO, cup inclination and stem version were 1.0 and 1.0, 0.98 and 0.98, 0.99 and 0.99, and 1.0 and 0.97, for observers 1 and 2, respectively. The interclass correlation coefficients indicating interobserver variation for cup open face version, cup ALO, cup inclination and stem version were 1.0, 0.99, 0.99 and 0.99, respectively.

Conclusion

The reported technique for measurement of BFX total hip replacement implant orientation is highly repeatable and allows objective measurement of implant orientation, including parameters which are not accessible radiographically.

Zitieren

APA

Pink, J., & Bilmont, A. (2026). Computed Tomographic Measurement of Cementless Total Hip Replacement Implant Orientation. Veterinary and Comparative Orthopaedics and Traumatology. https://doi.org/10.1055/a-2889-7878

Vancouver

Pink J, Bilmont A. Computed Tomographic Measurement of Cementless Total Hip Replacement Implant Orientation. Veterinary and Comparative Orthopaedics and Traumatology. 2026. doi:10.1055/a-2889-7878

BibTeX
@article{Pink2026,
  author = {Pink, Jonathan and Bilmont, Alexis},
  title = {Computed Tomographic Measurement of Cementless Total Hip Replacement Implant Orientation},
  journal = {Veterinary and Comparative Orthopaedics and Traumatology},
  year = {2026},
  doi = {10.1055/a-2889-7878}
}
Kostenlos starten →