EUVIMEDEUVIMED entdecken
Crossref

"Finger-Touch Approach" for Novice Microsurgical Assistants: A Simulation Study

„Finger-Touch Approach“ für unerfahrene mikroschirurgische Assistierende: eine Simulationsstudie

Ayaka Ogura, Shigeki Ishibashi iD, Toko Miyazaki, Reiko Tsukuura, Chihiro Matsui, Nana Yamamoto, Takumi Yamamoto

Journal of Reconstructive Microsurgery · 05.06.2026

DOI: 10.1055/a-2880-0416 ↗

Auf einen Blick

Bei jungen Assistierenden reduzierte der Finger-Touch Approach unbeabsichtigte Kontakte, ohne Zeit bis zum Operationsfeld oder Trajektorienvariabilität zu verändern. Bei erfahreneren Teilnehmenden zeigte sich kein signifikanter Unterschied.

Fragestellung

Verbessert der Finger-Touch Approach in einer Simulation die Sicherheit und das Sicherheitsgefühl bei mikroschirurgischer Assistenz ohne Effizienzverlust?

Methode

Simulationsstudie; Postgraduate-year 1 to 2 junior residents und plastic surgery residents/fellows führten eine Aufgabe mit konventioneller Methode und mit FTA durch.

Ergebnisse

18 JRs und 5 PSFs. Bei JRs weniger unbeabsichtigte Kontakte mit FTA als konventionell (0.1 vs. 0.0, p = 0.003); keine Unterschiede bei Zeit bis zum Feld oder Trajektorienvariabilität. Bei PSFs keine signifikanten Unterschiede.

Schlussfolgerung der Autor:innen

FTA verbessert nach Autorenangabe Sicherheit und psychologisches Wohlbefinden bei unerfahrenen mikroschirurgischen Assistierenden. Die Technik erfordert nur minimale Einweisung und kein zusätzliches Equipment.

Kernaussagen

  • JRs: weniger unbeabsichtigte Kontakte mit FTA
  • Kein Effekt auf Zeit bis zum Feld oder Trajektorienvariabilität
  • Positivere psychologische Reaktionen bei JRs als bei PSFs

Deutsche Zusammenfassung: KI-gestützt aus dem Original-Abstract erstellt; alle Zahlen wurden automatisch mit dem Original abgeglichen. Maßgeblich ist der Original-Abstract.

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Reconstructive Microsurgery, erschienen am 05.06.2026. Verfasst von Ayaka Ogura und 6 weiteren Autor:innen. Beteiligte Einrichtung: National Center for Global Health and Medicine, Department of Medical Education, Japan, Tokyo.

Auf einen BlickAbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Microsurgical procedures demand precise hand–eye coordination, yet the surgeon's hands often remain outside the visual field until instruments enter the microscope view, impairing spatial awareness. We developed the finger-touch approach (FTA) to provide an additional proprioceptive reference point, hypothesizing it would improve safety and confidence without compromising efficiency.

Methods

A simulation task was designed to replicate microsurgical suture-cutting assistance, one of the most common procedures performed by a microsurgery assistant. Postgraduate-year 1 to 2 junior residents (JR), and plastic surgery residents/fellows (PSF) performed the task using two approaches: a conventional method and the FTA, which involved touching the instrument to the assistant's index finger before entering the microscopic field. The number of unintended contacts, time to reach the microscopic field, and trajectory variability were measured. Microsurgical precision and psychological responses were compared between the methods.

Results

Eighteen JRs and five PSFs participated. FTA significantly reduced unintended contacts among JRs compared with the conventional approach (0.1 vs. 0.0, p = 0.003), without affecting the time to reach the field or trajectory variability. In contrast, no significant differences were observed among PSFs. Posttask questionnaire revealed higher positive psychological responses among JRs compared with PSFs in comfort with the FTA (94.4% vs. 40.0%, p = 0.021) and interest in incorporating the technique into actual surgery (100% vs. 60.0%, p = 0.040).

Conclusion

FTA improves safety and psychological comfort among novice microsurgical assistants. The technique requires minimal instruction without additional equipment, making it readily implementable in training programs and clinical practices for beginners.

Autor:innen und Institutionen

  • National Center for Global Health and Medicine, Department of Medical Education, Japan, Tokyo.
  • National Center for Global Health and Medicine Hospital, Supermicrosurgery, Tokyo, Japan, Shinjuku-ku.
  • Hiroshima University, Department of Orthopaedic Surgery, Japan, Hiroshima.
  • Juntendo University School of Medicine, Plastic and Reconstructive Surgery, Japan, Tokyo.

ORCID-Profile: Shigeki Ishibashi

Zitieren

APA

Ogura, A., Ishibashi, S., Miyazaki, T., Tsukuura, R., Matsui, C., Yamamoto, N., & Yamamoto, T. (2026). "Finger-Touch Approach" for Novice Microsurgical Assistants: A Simulation Study. Journal of Reconstructive Microsurgery. https://doi.org/10.1055/a-2880-0416

Vancouver

Ogura A, Ishibashi S, Miyazaki T, Tsukuura R, Matsui C, Yamamoto N, et al. "Finger-Touch Approach" for Novice Microsurgical Assistants: A Simulation Study. Journal of Reconstructive Microsurgery. 2026. doi:10.1055/a-2880-0416

BibTeX
@article{Ogura2026,
  author = {Ogura, Ayaka and Ishibashi, Shigeki and Miyazaki, Toko and Tsukuura, Reiko and Matsui, Chihiro and Yamamoto, Nana and Yamamoto, Takumi},
  title = {"Finger-Touch Approach" for Novice Microsurgical Assistants: A Simulation Study},
  journal = {Journal of Reconstructive Microsurgery},
  year = {2026},
  doi = {10.1055/a-2880-0416}
}
Kostenlos starten →