EUVIMEDEUVIMED entdecken
Open Access

Low Remote Patient Monitoring Utilization is Strongly Associated with Uncontrolled Hypertension in a Mixed-Race Sample of Urban-Dwelling Patients

John M Meddar iD, Maria R Khan, Mark Schwartz, Hyung G Park, Rachel Engelberg, Devin Mann

Applied Clinical Informatics · 01.05.2026 · 17 (03) · 400-411

DOI: 10.1055/a-2876-7314 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Applied Clinical Informatics, erschienen am 01.05.2026. Verfasst von John M Meddar und 5 weiteren Autor:innen. Beteiligte Einrichtung: New York University Grossman School of Medicine, Department of Population Health, New York, United States, New York. Hauptthemen laut MEDLINE: Hypertension, Remote Patient Monitoring. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: AHRQ HHS, U.S. National Library of Medicine.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The coronavirus disease 2019 (COVID-19) pandemic spurred a tremendous increase in the adoption and use of remote patient monitoring (RPM) for hypertension (HTN) management. However, limited evidence exists on the associations between frequency of utilization and uncontrolled blood pressure (BP).

Objectives

The present study comprehensively explores the associations between RPM use frequency and uncontrolled BP among a metropolitan-dwelling sample of hypertensive patients.

Methods

Of 2,920 participants from a single urban health system, we employed a range of analytical perspectives to evaluate the RPM utilization–uncontrolled BP relationship across widely used engagement metrics: Frequency of BP transmission, digitally enabled clinician interactions, patient portal interactions, and a composite measure of utilization. Our dichotomized primary and secondary endpoints were BP >140/90 mm Hg and BP >130/80 mm Hg.

Results

Fifty-nine percent of participants were females (59%), one-third (37%) were ≥65 years old, and Hispanic patients were most represented (39%). Our primary uncontrolled BP endpoint demonstrated strong adjusted associations with suboptimal RPM use across dichotomized measures: Low BP transmission (odds ratio [OR]: 2.02, 95% confidence interval [CI]: 1.41–2.96), low clinician interactions (OR: 1.83, 95% CI: 1.43–2.36), low patient portal interactions (OR: 1.83, 95% 1.46–2.30), and low overall engagement (OR: 3.50, 95% 2.77–4.46). Our causal evaluations mirrored these findings, showing moderate causal associations after comprehensive adjustment for confounding. Assessments using other data types, such as continuous and quartiles, showed significant associations and an apparent dose–response relationship, though not at a similar magnitude.

Conclusion

We observed strong associations between low RPM utilization and uncontrolled BP, with promising implications for patients with collectively high RPM use. These findings highlight the need to strengthen digital inclusion initiatives to improve RPM uptake and support existing efforts aimed at developing RPM clinical practice guidelines and expanding RPM reimbursement policies. Further research is warranted across diverse utilization components to better understand the linkages between engagement frequency and improved clinical outcomes.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

HypertensionRemote Patient MonitoringAgedFemaleHumansMaleMiddle AgedDigital HealthUrban PopulationPatient Acceptance of Health CarePrevalenceRetrospective StudiesLongitudinal StudiesWhiteBlack or African AmericanHispanic or LatinoNew York City

Autor:innen und Institutionen

  • New York University Grossman School of Medicine, Department of Population Health, New York, United States, New York.
  • University of Washington, Department of Biomedical Informatics and Medical Education, Washington, United States, Seattle.
  • Mount Sinai Health System, Department of Internal Medicine, New York, United States, New York.

ORCID-Profile: John M Meddar

Förderung

  • AHRQ HHS
  • U.S. National Library of Medicine

Zitieren

APA

Meddar, J. M., Khan, M. R., Schwartz, M., Park, H. G., Engelberg, R., & Mann, D. (2026). Low Remote Patient Monitoring Utilization is Strongly Associated with Uncontrolled Hypertension in a Mixed-Race Sample of Urban-Dwelling Patients. Applied Clinical Informatics, 17(03), 400-411. https://doi.org/10.1055/a-2876-7314

Vancouver

Meddar JM, Khan MR, Schwartz M, Park HG, Engelberg R, Mann D. Low Remote Patient Monitoring Utilization is Strongly Associated with Uncontrolled Hypertension in a Mixed-Race Sample of Urban-Dwelling Patients. Applied Clinical Informatics. 2026;17(03):400-411. doi:10.1055/a-2876-7314

BibTeX
@article{Meddar2026,
  author = {Meddar, John M and Khan, Maria R and Schwartz, Mark and Park, Hyung G and Engelberg, Rachel and Mann, Devin},
  title = {Low Remote Patient Monitoring Utilization is Strongly Associated with Uncontrolled Hypertension in a Mixed-Race Sample of Urban-Dwelling Patients},
  journal = {Applied Clinical Informatics},
  year = {2026},
  volume = {17},
  number = {03},
  pages = {400--411},
  doi = {10.1055/a-2876-7314}
}
Kostenlos starten →