Non-Scar Fixation Technique for Zygomaticomaxillary Complex Tripod Fracture Using Upper Lid Transconjunctival Incision
Archives of Plastic Surgery · 01.05.2026 · 53 (03) · 234-240
DOI: 10.1055/a-2875-5296 ↗Kurz gefasst
Fachartikel in der Zeitschrift Archives of Plastic Surgery, erschienen am 01.05.2026. Verfasst von Han Gyu Cha und 4 weiteren Autor:innen. Beteiligte Einrichtung: College of Medicine, Department of Plastic and Reconstructive SurgerySoonchunhyang University Bucheon Hospital, Soonchunhyang UniversityBucheonKorea. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Background
Surgical approaches for zygomaticomaxillary complex (ZMC) fractures have evolved toward minimizing cutaneous incisions while maintaining adequate exposure. Conventional approaches for frontozygomatic fixation, such as lateral brow or transconjunctival incisions with lateral extension, may result in visible scarring or periocular complications. Building on previous transconjunctival techniques, we applied an independent upper eyelid transconjunctival incision as a non-cutaneous approach for frontozygomatic fixation in selected ZMC tripod fractures.
Methods
This retrospective comparative study included 27 patients with unilateral ZMC tripod fractures, of whom 12 underwent non-scar fixation using an upper eyelid transconjunctival approach, and 15 underwent fixation through preexisting periorbital traumatic lacerations. The surgical strategy consisted of initial reduction and fixation via an intraoral approach, followed by selective additional fixation of the frontozygomatic region when residual step deformity or instability was present. Preoperative and 6-month postoperative computed tomography and three-dimensional photogrammetry were used to evaluate bony and soft tissue intermalar height differences.
Results
Preoperative intermalar height differences were comparable between groups. At 6 months postoperatively, both groups showed marked improvement, with bony differences of −0.2 ± 1.2 mm and −0.4 ± 0.4 mm, and soft tissue differences of 0.0 ± 0.6 mm and −0.2 ± 0.7 mm in the non-scar and control groups, respectively, with no clinically meaningful between-group differences. No clinically significant approach-related ophthalmic complications were observed.
Conclusions
The upper eyelid transconjunctival approach is a reliable non-cutaneous option for frontozygomatic fixation in selected ZMC tripod fractures, providing adequate exposure and stable fixation without visible scarring.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- College of Medicine, Department of Plastic and Reconstructive SurgerySoonchunhyang University Bucheon Hospital, Soonchunhyang UniversityBucheonKorea.
ORCID-Profile: Han Gyu Cha, Seo Koo Lee, Joon Suk Bae, Seung Min Nam, Eun Soo Park
Zitieren
APA
Cha, H. G., Lee, S. K., Bae, J. S., Nam, S. M., & Park, E. S. (2026). Non-Scar Fixation Technique for Zygomaticomaxillary Complex Tripod Fracture Using Upper Lid Transconjunctival Incision. Archives of Plastic Surgery, 53(03), 234-240. https://doi.org/10.1055/a-2875-5296
Vancouver
Cha HG, Lee SK, Bae JS, Nam SM, Park ES. Non-Scar Fixation Technique for Zygomaticomaxillary Complex Tripod Fracture Using Upper Lid Transconjunctival Incision. Archives of Plastic Surgery. 2026;53(03):234-240. doi:10.1055/a-2875-5296
BibTeX
@article{Cha2026,
author = {Cha, Han Gyu and Lee, Seo Koo and Bae, Joon Suk and Nam, Seung Min and Park, Eun Soo},
title = {Non-Scar Fixation Technique for Zygomaticomaxillary Complex Tripod Fracture Using Upper Lid Transconjunctival Incision},
journal = {Archives of Plastic Surgery},
year = {2026},
volume = {53},
number = {03},
pages = {234--240},
doi = {10.1055/a-2875-5296}
}
EUVIMED