EUVIMEDEUVIMED entdecken
Open Access

Linear Versus Curved Incision for Transcutaneous Bone Conduction Implants: Comparative Scar Assessment

Leonardo Elías Ordóñez-Ordóñez iD, José Agustín Caraballo-Arias iD, Hernán Díaz-Badillo iD, Paola Andrea Medina-Bravo iD, Camilo Macias-Tolosa iD, Jorge Alexis Medina-Parra iD, Esther Sofía Angulo-Martínez iD, Estefany Catherine Hernández iD

International Archives of Otorhinolaryngology · 01.07.2026 · 30 (03) · 001-011

DOI: 10.1055/a-2852-9524 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Archives of Otorhinolaryngology, erschienen am 01.07.2026. Verfasst von Leonardo Elías Ordóñez-Ordóñez und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Otolaryngology, Clínica Universitaria Colombia, Clínicas Colsanitas SA, Keralty, Colombia. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

In some patients with conductive or mixed hearing loss, or single-sided deafness, bone conduction implants (BCIs) offer an effective treatment; and scar appearance is a relevant factor in the overall outcome.

Objective

To compare scar appearance and alopecia between linear and curved scalp incisions in patients undergoing transcutaneous BCIs surgery.

Methods

An observational, cross-sectional study was conducted at a tertiary referral center in patients who underwent transcutaneous BCI. Postoperative follow-up period was between 6m to 3y. Scar evaluation was performed using the Patient and Observer Scar Assessment Scale (POSAS) and the Vancouver Scar Scale (VSS). Alopecia was defined as absence of hair follicles within 2 mm of the incision line. Statistical comparisons between linear and curved incisions groups were conducted, as well as multivariate analysis with logistic regression models.

Results

Eighty-four cases were analyzed: 28 underwent linear incisions and 56 underwent curved incisions. Patients reported significantly better scar appearance with linear incisions in POSAS, p = 0.035. Alopecia occurred less frequently among patients who received the Bonebridge implant (OR = 0.113; 95% CI: 0.027–0.478; p = 0.003). No statistically significant differences were found in observer assessment of POSAS or VSS scores.

Conclusion

Linear incisions may offer advantages in scar appearance with transcutaneous BCIs. Certain scar characteristics may also be influenced by the type of device and the surgical approach required for its placement, making it challenging to isolate this effect from that attributed solely to type of incision. These results highlight the need to consider both cosmetic factors and auditory outcomes in surgical planning.

Schlagwörter

Stichwörter der Autor:innen

bone conduction implantconductive hearing lossmixed hearing losspatient and observer scar assessment scalepatient-reported outcomes

Autor:innen und Institutionen

  • Department of Otolaryngology, Clínica Universitaria Colombia, Clínicas Colsanitas SA, Keralty, Colombia.
  • Department of Otolaryngology, Facultad de Medicina, Fundación Universitaria Sanitas (Unisanitas), Keralty, Colombia.
  • Hospital Militar Central, Universidad Militar Nueva Granada, Bogotá, Colombia.
  • Anaboleas Research Team, Endorsed by Clínica Universitaria Colombia and Fundación Universitaria Sanitas (Unisanitas). Recognized by Colciencias (2024) Ministry of Science, Technology and Innovation of Colombia, Colombia.
  • Department of Otolaryngology, Clínica Los Nogales, Bogotá, Colombia.

ORCID-Profile: Leonardo Elías Ordóñez-Ordóñez, José Agustín Caraballo-Arias, Hernán Díaz-Badillo, Paola Andrea Medina-Bravo, Camilo Macias-Tolosa, Jorge Alexis Medina-Parra, Esther Sofía Angulo-Martínez, Estefany Catherine Hernández

Zitieren

APA

Ordóñez-Ordóñez, L. E., Caraballo-Arias, J. A., Díaz-Badillo, H., Medina-Bravo, P. A., Macias-Tolosa, C., Medina-Parra, J. A., Angulo-Martínez, E. S., & Hernández, E. C. (2026). Linear Versus Curved Incision for Transcutaneous Bone Conduction Implants: Comparative Scar Assessment. International Archives of Otorhinolaryngology, 30(03), 001-011. https://doi.org/10.1055/a-2852-9524

Vancouver

Ordóñez-Ordóñez LE, Caraballo-Arias JA, Díaz-Badillo H, Medina-Bravo PA, Macias-Tolosa C, Medina-Parra JA, et al. Linear Versus Curved Incision for Transcutaneous Bone Conduction Implants: Comparative Scar Assessment. International Archives of Otorhinolaryngology. 2026;30(03):001-011. doi:10.1055/a-2852-9524

BibTeX
@article{OrdezOrdez2026,
  author = {Ordóñez-Ordóñez, Leonardo Elías and Caraballo-Arias, José Agustín and Díaz-Badillo, Hernán and Medina-Bravo, Paola Andrea and Macias-Tolosa, Camilo and Medina-Parra, Jorge Alexis and Angulo-Martínez, Esther Sofía and Hernández, Estefany Catherine},
  title = {Linear Versus Curved Incision for Transcutaneous Bone Conduction Implants: Comparative Scar Assessment},
  journal = {International Archives of Otorhinolaryngology},
  year = {2026},
  volume = {30},
  number = {03},
  pages = {001--011},
  doi = {10.1055/a-2852-9524}
}
Kostenlos starten →