Fachartikel in der Zeitschrift International Archives of Otorhinolaryngology, erschienen am 01.07.2026. Verfasst von Raghav Katyal und 1 weiteren Autor:innen. Beteiligte Einrichtung: Nitte Institute of Speech and Hearing, K S Hegde Medical Academy, Nitte (Deemed to be University), Mangalore, Karnataka, India. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Masseteric vestibular evoked myogenic potentials assess saccular-masseteric pathway function using air-conducted or bone-conducted stimuli.

Objective

This study investigated whether simulated bilateral conductive hearing loss differentially affects mVEMP response characteristics under air- and bone-conducted stimulation in young adults.

Methods

Fifty healthy participants were included in the study. Conductive hearing loss was simulated in 25 individuals using silicone-blocked foam ear tips to create controlled bilateral attenuation. Masseteric vestibular evoked myogenic potentials were elicited using 500 Hz tone bursts delivered to the right ear through air and bone-conducted methods. Responses were recorded using a two-channel zygomatic electrode placement and analyzed for P1 and N1 latencies and P1-N1 peak-to-peak amplitude.

Results

In the simulated conductive hearing loss group, air-conducted masseteric vestibular evoked myogenic potential responses showed decreased response rate, delayed latency, and reduced amplitude compared with normal hearing participants. In contrast, bone-conducted masseteric vestibular evoked myogenic potentials were consistently recorded in both groups, demonstrating significantly higher amplitudes and earlier latencies than air-conducted responses in the simulated conductive hearing loss group. Spectral analysis revealed a consistent peak around 100 Hz for all conditions except air-conducted stimulation in the simulated conductive hearing loss group, which showed no distinct peak.

Conclusion

Simulated conductive hearing loss significantly affects air-conducted masseteric vestibular evoked myogenic potential responses, often rendering them absent or diminished. However, bone-conducted responses remain robust and reliable in normal and simulated conductive hearing loss conditions, highlighting their diagnostic value when conductive pathologies compromise air-conducted responses.

Schlagwörter

Stichwörter der Autor:innen

Masseter VEMPbone conductionconductive hearing lossocclusion effectvestibular evoked myogenic potential

Autor:innen und Institutionen

  • Nitte Institute of Speech and Hearing, K S Hegde Medical Academy, Nitte (Deemed to be University), Mangalore, Karnataka, India.

ORCID-Profile: Jim Saroj Winston

Zitieren

APA

Katyal, R., & Winston, J. S. (2026). Air and Bone-Conduction Masseteric Vestibular Evoked Myogenic Potentials: A Simulated Conductive Hearing Loss Study. International Archives of Otorhinolaryngology, 30(03), 001-008. https://doi.org/10.1055/a-2846-4560

Vancouver

Katyal R, Winston JS. Air and Bone-Conduction Masseteric Vestibular Evoked Myogenic Potentials: A Simulated Conductive Hearing Loss Study. International Archives of Otorhinolaryngology. 2026;30(03):001-008. doi:10.1055/a-2846-4560

BibTeX
@article{Katyal2026,
  author = {Katyal, Raghav and Winston, Jim Saroj},
  title = {Air and Bone-Conduction Masseteric Vestibular Evoked Myogenic Potentials: A Simulated Conductive Hearing Loss Study},
  journal = {International Archives of Otorhinolaryngology},
  year = {2026},
  volume = {30},
  number = {03},
  pages = {001--008},
  doi = {10.1055/a-2846-4560}
}
Kostenlos starten →