The Utility of Transcutaneous Bilirubin Measurement in Newborns with Hyperbilirubinemia: A Prospective, Observational Study during and after Phototherapy
American Journal of Perinatology · 2026-10 · 43 (14) · 1913-1919
DOI: 10.1055/a-2841-9781 ↗Kurz gefasst
Beobachtungsstudie in der Zeitschrift American Journal of Perinatology, online erschienen am 10.04.2026. Verfasst von Duygu Besnili Acar und 1 weiteren Autor:innen. Beteiligte Einrichtung: Division of Neonatology, Department of Pediatrics, Istanbul Gaziosmanpasa Training and Research Hospital, Istanbul, Turkiye. Hauptthemen laut MEDLINE: Bilirubin, Hyperbilirubinemia, Neonatal, Phototherapy, Skin. Die Arbeit nennt 26 Literaturangaben.
Abstract (Originalsprache)
This study aimed to evaluate the accuracy of transcutaneous bilirubin (TcB) measurements during and after phototherapy (PT) in term and late-preterm infants. In this prospective, observational study, TcB levels were measured at both the glabela (covered skin) and the lower abdomen (covered by the diaper) during treatment, then 12 and 24 hours after discontinuing the PT. Total serum bilirubin (TSB) levels were simultaneously collected through a blood sample. The agreement between TcB and TSB levels during and after PT was evaluated using Bland–Altman plots. A total of 90 newborn infants and 540 paired bilirubin values were included in this study. The findings indicate that despite a moderate correlation with TSB levels, TcB measurements underestimate TSB levels. This study indicates a moderate correlation and agreement between TcB measurements and TSB levels in term and late-preterm infants undergoing PT, with a tendency to underestimate TSB values and considerable variability between the two methods. Hence, TcB measurements cannot be relied upon as a substitute for TSB measurements during and after PT.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Division of Neonatology, Department of Pediatrics, Istanbul Gaziosmanpasa Training and Research Hospital, Istanbul, Turkiye.
- Division of Neonatology, Department of Pediatrics, Istinye University Liv Topkapi Hospital, Istanbul, Turkiye.
ORCID-Profile: Duygu Besnili Acar, Seda Yilmaz Semerci
Zitieren
APA
Besnili Acar, D., & Yilmaz Semerci, S. (2026). The Utility of Transcutaneous Bilirubin Measurement in Newborns with Hyperbilirubinemia: A Prospective, Observational Study during and after Phototherapy. American Journal of Perinatology, 43(14), 1913-1919. https://doi.org/10.1055/a-2841-9781
Vancouver
Besnili Acar D, Yilmaz Semerci S. The Utility of Transcutaneous Bilirubin Measurement in Newborns with Hyperbilirubinemia: A Prospective, Observational Study during and after Phototherapy. American Journal of Perinatology. 2026;43(14):1913-1919. doi:10.1055/a-2841-9781
BibTeX
@article{BesniliAcar2026,
author = {Besnili Acar, Duygu and Yilmaz Semerci, Seda},
title = {The Utility of Transcutaneous Bilirubin Measurement in Newborns with Hyperbilirubinemia: A Prospective, Observational Study during and after Phototherapy},
journal = {American Journal of Perinatology},
year = {2026},
volume = {43},
number = {14},
pages = {1913--1919},
doi = {10.1055/a-2841-9781}
}