EUVIMEDEUVIMED entdecken
Open Access

Stewardship of Inpatient A1c Testing: An Electronic Nudge to Limit Testing after Red Cell Transfusion

Andrew A White iD, Brent E Wisse

Applied Clinical Informatics · 01.03.2026 · 17 (02) · 190-193

DOI: 10.1055/a-2838-8292 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Applied Clinical Informatics, erschienen am 01.03.2026. Verfasst von Andrew A White und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medicine, University of Washington School of Medicine, Seattle, Washington, United States. Hauptthemen laut MEDLINE: Erythrocyte Transfusion, Glycated Hemoglobin, Inpatients. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Guidelines recommend measuring glycated hemoglobin (HgbA1c) levels on all inpatients with diabetes mellitus, if untested in the prior 3 months. In response, our health system applies default HgbA1c orders in the electronic insulin orders for qualifying patients. However, recent red blood cell transfusions may cause falsely low HgbA1c values, leading to inappropriate management. Clinicians often forget to deselect default HgbA1c orders after transfusion, leading to erroneous results. We evaluated a non-interruptive clinical decision support (CDS) intervention to discourage automatic HgbA1c testing in patients with recent transfusions.

Methods

A retrospective, observational analysis of the number and percentage of HgbA1c tests performed on inpatients within 7 days of a red blood cell transfusion over a 40-month period.

Results

Preintervention, clinicians ordered an average of 827 HgbA1c tests/month on inpatients. Of these, 11.7% (97 tests/month) were on patients who received a red blood cell transfusion within the preceding 7 days. Postintervention, clinicians ordered an average of 832 HgbA1c tests per month on inpatients, of which 5.8% (48 tests/month) were performed within 7 days of red blood cell transfusions.

Conclusion

A non-interruptive CDS intervention can significantly decrease the number of HgbA1c tests performed in hospitalized patients who received a red blood cell transfusion, a common cause of erroneous HgbA1c values. This approach reduced waste without restricting clinician autonomy or requiring interruptive alerts that generate alert fatigue.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Erythrocyte TransfusionGlycated HemoglobinInpatientsHumansDecision Support Systems, Clinical

Substanzen

Glycated Hemoglobin

Autor:innen und Institutionen

  • Department of Medicine, University of Washington School of Medicine, Seattle, Washington, United States.

ORCID-Profile: Andrew A White

Zitieren

APA

White, A. A., & Wisse, B. E. (2026). Stewardship of Inpatient A1c Testing: An Electronic Nudge to Limit Testing after Red Cell Transfusion. Applied Clinical Informatics, 17(02), 190-193. https://doi.org/10.1055/a-2838-8292

Vancouver

White AA, Wisse BE. Stewardship of Inpatient A1c Testing: An Electronic Nudge to Limit Testing after Red Cell Transfusion. Applied Clinical Informatics. 2026;17(02):190-193. doi:10.1055/a-2838-8292

BibTeX
@article{White2026,
  author = {White, Andrew A and Wisse, Brent E},
  title = {Stewardship of Inpatient A1c Testing: An Electronic Nudge to Limit Testing after Red Cell Transfusion},
  journal = {Applied Clinical Informatics},
  year = {2026},
  volume = {17},
  number = {02},
  pages = {190--193},
  doi = {10.1055/a-2838-8292}
}
Kostenlos starten →