Bridging the Gap between Microsurgery and Supermicrosurgery: A Rat Study for 0.3 mm Vascular Anastomosis Comparing Robotic-assisted vs. Conventional Approach
Journal of Reconstructive Microsurgery · 01.07.2026 · 42 (06) · 533-540
DOI: 10.1055/a-2824-6437 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Journal of Reconstructive Microsurgery, erschienen am 01.07.2026. Verfasst von Tae Hyung Kim und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Plastic and Reconstructive Surgery, Asan Medical Center, University of Ulsan College of Medicine, Seoul, South Korea. Hauptthemen laut MEDLINE: Microsurgery, Anastomosis, Surgical, Robotic Surgical Procedures, Femoral Artery. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Background
Supermicrosurgery involving vessels ≤0.3 mm remains among the most technically demanding procedures in reconstructive surgery. Robotic platforms have shown potential to enhance precision, but their feasibility at this extreme scale requires further validation.
Methods
Apprentice surgeons (≤5 years' experience) performed rat femoral vessel (approximately 0.26–0.30 mm) anastomoses using both hand-sewn and robotic-assisted techniques across eight consecutive trials. Outcome measures included Structured Assessment of Robotic Microsurgical Skills (SARMS) scores, operative time, stitch count, and patency rate. Learning curves were assessed with cumulative summation (CUSUM) analysis, and anastomotic quality was evaluated using scanning electron microscopy (SEM).
Results
Robotic-assisted anastomosis reached proficiency earlier than hand-sewn repair (4th versus 6th trial). Although initial operative time was longer for robotic cases (1,772 ± 120 seconds versus 1,355 ± 187 seconds, p = 0.013), times equalized by the 5th trial and decreased by 42% by the 8th (1,026 ± 58 seconds versus 1,023 ± 73 seconds, p = 0.959). Stitch counts were higher in later robotic trials (4.2 ± 0.6 versus 3.5 ± 0.5, p = 0.015). Both groups achieved 100% patency by the 4th trial. CUSUM and SEM analyses confirmed a steeper learning curve and superior anastomotic precision with robotic assistance.
Conclusion
Robotic-assisted supermicrosurgery enables earlier proficiency, enhanced precision, and reproducible anastomotic quality compared with hand-sewn techniques. Despite longer initial times, robotic performance rapidly improved, achieving equivalent efficiency with greater technical control. These findings confirm the technical feasibility of robotic supermicrosurgery at the 0.3 mm scale and support its potential role in microsurgical and lymphatic reconstruction training and clinical practice.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Plastic and Reconstructive Surgery, Asan Medical Center, University of Ulsan College of Medicine, Seoul, South Korea.
ORCID-Profile: Tae Hyung Kim, Joon Pio Hong
Zitieren
APA
Kim, T. H., Chae, S., Kim, D., Kim, T., Kwon, J. G., Pak, C. J., Suh, H. P., & Hong, J. P. (2026). Bridging the Gap between Microsurgery and Supermicrosurgery: A Rat Study for 0.3 mm Vascular Anastomosis Comparing Robotic-assisted vs. Conventional Approach. Journal of Reconstructive Microsurgery, 42(06), 533-540. https://doi.org/10.1055/a-2824-6437
Vancouver
Kim TH, Chae S, Kim D, Kim T, Kwon JG, Pak CJ, et al. Bridging the Gap between Microsurgery and Supermicrosurgery: A Rat Study for 0.3 mm Vascular Anastomosis Comparing Robotic-assisted vs. Conventional Approach. Journal of Reconstructive Microsurgery. 2026;42(06):533-540. doi:10.1055/a-2824-6437
BibTeX
@article{Kim2026,
author = {Kim, Tae Hyung and Chae, Seohee and Kim, Donggeon and Kim, Taehyun and Kwon, Jin Geun and Pak, Changsik John and Suh, Hyunsuk Peter and Hong, Joon Pio},
title = {Bridging the Gap between Microsurgery and Supermicrosurgery: A Rat Study for 0.3 mm Vascular Anastomosis Comparing Robotic-assisted vs. Conventional Approach},
journal = {Journal of Reconstructive Microsurgery},
year = {2026},
volume = {42},
number = {06},
pages = {533--540},
doi = {10.1055/a-2824-6437}
}